Fluke 8050A – Digital Multimeter

The Fluke 8050A is a precision digital multimeter for electronic testing and measurement. It features a clear digital display, wide measurement ranges for voltage, current, and resistance, and user-friendly interface. Ideal for electronics troubleshooting, circuit testing, and general-purpose measurements.

Model
Fluke 8050A
Calibration
Available on request
Price
$110
Status
In stock
RFQ ref
8050A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 8050A is a 4-1/2 digit LCD digital multimeter engineered for precision measurement across DC/AC voltage, current, resistance, conductance, and specialized functions. Dual-slope integration analog-to-digital conversion delivers noise-free measurements with 0.03% basic DC accuracy and 1-year calibration stability. Built-in overload and transient protection (up to 6 kV, 10 microseconds) ensure reliable operation in demanding field and laboratory environments.

Technical Specifications Voltage & Current Measurement

DC voltage: 10 µV to 1000 V, ±(0.03% of reading + 2 digits)

AC voltage (True RMS): 10 mV to 750 V, 20 Hz to 50 kHz with -3 dB point at 200 kHz

DC current: 10 nA to 2 A

AC current (True RMS): 10 µA to 2 A Resistance & Conductance

Resistance: 10 mΩ to 20 MΩ; ranges supply sufficient voltage for PN junction testing

Conductance: Up to 100,000 MΩ equivalent resistance Advanced Functions

Diode and transistor testing

Decibel measurements (dBm) referenced to 16 user-selectable impedances

Relative reference offset capability across all measurement functions

dB voltage measurements with configurable reference impedances Display & Protection

4-1/2 digit LCD with automatic polarity and overrange indication

Input impedance: 10 MΩ in parallel with 60 dB at 60 Hz or 50 Hz (1 kΩ unbalance)

Fuse-protected input connector for current measurements

Key Features

Dual-slope integration ensures noise immunity and long-term stability

True RMS AC measurement from 20 Hz to 50 kHz

Extended frequency response to 200 kHz

Transient overvoltage protection to 6 kV, 10 microseconds

Full overload protection across all functions and ranges

Typical Applications Electronic circuit troubleshooting, component characterization, field service diagnostics, laboratory measurements, and diode/transistor verification.

Compatibility & Integration Standard test lead connectivity with fused input protection for safe current measurement operations.

Specifications

ParameterValue
Frequency Range20 Hz to 50 kHz (True RMS)
-3 dB at 200 kHz | Voltage / Current RangeDC voltage: 10 µV to 1000 V
AC voltage10 mV to 750 V
DC current10 nA to 2 A
AC current10 µA to 2 A

Fluke 8050A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 8050A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 8050A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 8050A price

This Fluke 8050A is listed at $110. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 8050A calibration cost

NIST-traceable calibration for the Fluke 8050A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents