Agilent/Keysight 5086-7906 (5086-6906)

The Agilent/Keysight 5086-7906 (5086-6906) is a component designed for use in various electronic systems. This component is sourced from trusted manufacturers, ensuring reliability and optimal performance in demanding applications.

Model
Agilent / Keysight 5086-7906/5086-6906
Calibration
Available on request
Price
$150
Status
In stock
RFQ ref
5086-7906/5086-6906
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 5086-7906 (5086-6906) is a YIG tuned oscillator (YTO) that generates stable, electronically tunable microwave signals for spectrum analyzer applications. This component enables precise frequency control and continuous swept analysis across extended RF and microwave bands, serving as a critical local oscillator in the 8560E series analyzer family and related instruments. The oscillator delivers clean, phase-stable output with tuning sensitivity of approximately 43 MHz per 1 mA of tuning current, supporting both wide dynamic range and synthesized frequency stepping.


Technical Specifications



  • Frequency range: 2 GHz to 20 GHz (YIG oscillator nominal operating band); compatible analyzers achieve 30 Hz to 26.5 GHz continuous sweep

  • Tuning sensitivity: 43 MHz per 1 mA of tuning current

  • Power supply requirements: +20 V and −10 V

  • Tuning current: 42 mA at 1.8 GHz; 110 mA at 4.6 GHz

  • Mixer output level: −43.3 dBm (typical); specification range −38 dBm to −45 dBm

  • Associated filter insertion loss: −0.14 dB at 3.914 GHz


Key Features



  • Electronic tuning across 2–20 GHz core band with extended low-frequency operation to 1.8 GHz

  • Continuous frequency sweep capability supporting analyzer measurements from 30 Hz to 26.5 GHz

  • Stable output performance with minimal phase noise characteristics

  • Current-tuned architecture enabling rapid frequency stepping and synthesis


Typical Applications



  • Local oscillator for RF/microwave spectrum analysis

  • Broadband frequency sweep in receiver test systems

  • Component replacement in field-service and upgrade scenarios for 8560E-series instruments


Compatibility & Integration The 5086-7906 (5086-6906) is a replacement component for Agilent/Keysight spectrum analyzers: 8560E, 8560EC, 8560EL, 8561E, 8561EC, 8562E, 8562EC, 8563E, 8563EC, 8564E, 8564EC, 8565E, and 8565EC series. It integrates into the analyzer's local oscillator and tuning circuits as a modular assembly.

Specifications

ParameterValue
Frequency Range2 GHz to 20 GHz (YIG band)
30 Hz to 26.5 GHz (analyzer system range) | Power Range (dBm)−43.3 dBm typical (−38 dBm to −45 dBm specification range) | Voltage / Current Range: '+20 V, −10 V

Agilent / Keysight 5086-7906/5086-6906 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 5086-7906/5086-6906. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight 5086-7906/5086-6906 faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Agilent / Keysight 5086-7906/5086-6906 price

This Agilent / Keysight 5086-7906/5086-6906 is listed at $150. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 5086-7906/5086-6906 calibration cost

NIST-traceable calibration for the Agilent / Keysight 5086-7906/5086-6906 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →