EADS / Racal / Dana 6061A Synthesized Signal Generator
EADS / Racal / Dana RF Signal Sources. Frequency range: 10 kHz to 1050 MHz, Resolution: 10 Hz steps, Resolution: 0.1 dB steps.
- Model
- EADS / Racal / Dana 6061A
- Calibration
- Available on request
- Price
- $1,250
- Status
- In stock
- RFQ ref
- 6061A
This unit
The EADS/Racal/Dana 6061A is a synthesized signal generator delivering precise RF signal generation from 10 kHz to 1050 MHz with 10 Hz frequency resolution. Purpose-built for receiver testing, component evaluation, and general RF applications, this VXIbus module combines signal generation with integrated analog and digital I/O channels. Superior phase noise performance - typical –123 dBc/Hz at 20 kHz offset from a 500 MHz carrier - distinguishes the 6061A from related models, making it especially valuable for low-noise receiver characterization.
Technical Specifications RF Performance
Frequency range: 10 kHz to 1050 MHz
Frequency resolution: 10 Hz steps
Frequency switching speed: <100 ms to within 100 Hz of final frequency
Output level range: –147 dBm to +13 dBm (overrange to +19 dBm)
Level resolution: 0.1 dB steps
Level accuracy: ±1 dB (–127 dBm to +13 dBm)
Phase noise (typical): –123 dBc/Hz at 20 kHz offset, 500 MHz carrier
Spurious performance: <–60 dBc (non-harmonic), 4.3 kHz (8 channels), >11 kHz (1 channel)
Channel isolation: 750 V between channels and to ground Digital Channels
32 channels, software configurable (16 input/16 output or 32 input/output)
Standard: current receiver inputs, open collector outputs
Key Features
SCPI-compatible, message-based programming
Full self-test covering analog and digital channels
Optional analog output ranges (current sourcing: ±1.6 V to ±16 V)
Optional TTL digital I/O
Residual FM specifications rated across 0° to 50°C operating range
Typical Applications
Receiver sensitivity and selectivity testing
RF component and subsystem evaluation
Low-noise signal sourcing for precision measurements
Multi-channel analog/digital test and control
Compatibility & Integration VXIbus form factor with integrated analog/digital architecture supports modular test system configurations. SCPI command compatibility enables integration with automated test sequences.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 kHz to 1050 MHz | Power Range (dBm): –147 dBm to +13 dBm (overrange to +19 dBm) | Voltage / Current Range: ±1 V, ±10 V (standard) |
EADS / Racal / Dana 6061A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the EADS / Racal / Dana 6061A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common EADS / Racal / Dana 6061A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
EADS / Racal / Dana 6061A price
This EADS / Racal / Dana 6061A is listed at $1,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
EADS / Racal / Dana 6061A calibration cost
NIST-traceable calibration for the EADS / Racal / Dana 6061A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →