Anritsu 68377C Synthesized High Performance Signal Generator, 10 MHz – 50 GHz
Anritsu 68377C,"High-performance signal generator operating from 10 MHz to 50 GHz, engineered for RF and microwave testing with superior spectral purity. Suitable for defense, satellite, and wireless communication applications. Offers precise signal output, fast frequency switching, and GPIB remote control for seamless integration into automated and lab test setups."
- Model
- Anritsu 68377C
- Calibration
- Available on request
- Price
- $10,279
- Status
- In stock
- RFQ ref
- 68377C
This unit
The Anritsu 68377C is a synthesized signal generator delivering precise RF and microwave stimulus across 10 MHz to 50 GHz for defense, satellite, and wireless communication test environments. The instrument combines ultra-low phase noise with accurate leveled output power down to −120 dBm in 0.01 dB steps, meeting stringent requirements for sensitive receiver characterization. Frequency switching completes in less than 5 ms, accelerating automated test sequences.
Its compact 13.3 cm footprint minimizes rack real estate while supporting SCPI programmability with IVI-COM and LabVIEW driver compatibility for seamless ATE integration.
Technical Specifications
Frequency Range & Resolution- 10 MHz to 50 GHz standard; optional extension to 0.1 Hz
- Waveguide extensions available to 110 GHz
- Frequency resolution: 100.0 mHz minimum; 0.1 Hz with Option 11 Output Power
- +12 dBm to −15 dBm typical (−20 dBm standard)
- +17 dBm guaranteed leveled power to 20 GHz
- Leveled output to −120 dBm in 0.01 dB steps
- Step attenuator options for 20 GHz, 40 GHz, 50 GHz, and 60 GHz bands
- High power output options for 2–20 GHz and 220 GHz ranges Phase Noise & Switching
- Ultra-low single-sideband phase noise: −107 dBc at 10 kHz offset from 10 GHz (example)
- Frequency switching: <5 ms; <5 ms for sweep steps <100 MHz Modulation Capabilities
- AM, FM, phase, pulse, and scan modulation
- Seven internal modulating waveforms plus user-defined options
- Internal Gaussian and uniform noise generators
- Advanced internal pulse modulation for single and multiple pulse sequences
- Pulse generator supports moving target simulation, radar analysis, and fading simulation
Key Features
- Broad 10 MHz–50 GHz coverage with optional sub-Hz and millimeter-wave extensions
- Superior spectral purity and fast frequency agility for dynamic test scenarios
- Compact form factor for space-constrained ATE racks
- Flexible modulation suite addresses radar, communications, and receiver testing
Typical Applications
- Receiver sensitivity and blocking characterization
- Radar blind spot and recovery time analysis
- Moving target and fading simulation studies
- Multi-band wireless and satellite communication testing
Compatibility & Integration SCPI programmability with IVI-COM and National Instruments LabVIEW driver support enable straightforward control and automation within existing test frameworks.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 50 GHz (standard) |
| waveguide extensions to 110 GHz | Power Range (dBm) | '+12 dBm to −15 dBm typical |
Anritsu 68377C — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu 68377C. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu 68377C faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Anritsu 68377C price
This Anritsu 68377C is listed at $10,279. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu 68377C calibration cost
NIST-traceable calibration for the Anritsu 68377C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →