Anritsu 69069A Synthesized CW Generator, 0.01 – 40 GHz

Anritsu 69069A,"Signal generator with 0.01 to 40 GHz coverage. Combines accuracy, speed, and stability for lab and field applications in RF testing."

Model
Anritsu 69069A
Calibration
Available on request
Price
$26,520
Status
In stock
RFQ ref
69069A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 69069A is a synthesized CW generator delivering precision frequency synthesis across 0.01 to 40 GHz. Built for RF component characterization, signal simulation, and automated test setups, this instrument combines fast switching, low phase noise, and stable frequency accuracy to meet the demands of laboratory and field-based RF engineers.


Technical Specifications

Frequency Performance

  • Range: 0.01 to 40 GHz

  • Resolution: 1 kHz (0.1 Hz with Option 11)

  • Aging rate (standard time base): < 2 × 10⁻⁸ per day

  • Aging rate (Option 16 high-stability time base): < 5 × 10⁻¹⁰ per day

  • Temperature coefficient (standard): < 2 × 10⁻⁸/°C over 0–55 °C

  • Temperature coefficient (Option 16): < 2 × 10⁻¹⁰/°C

  • Warm-up time from standby: 30 minutes

  • Warm-up from cold start (0 °C, standard): 120 hours to achieve < 2 × 10⁻⁸ per day Output Characteristics

  • Output impedance: 50 Ohms

  • Power resolution: 0.01 dB

  • Maximum leveled output: +10 dBm or manufacturer specification, whichever is lesser Signal Purity

  • SSB phase noise (typical): −100 dBc at 10 kHz offset from 10 GHz

  • Harmonic spurious (≥500 MHz to ≤2.2 GHz): < −50 dBc

  • Harmonic spurious (≥10 MHz to ≤50 MHz): 50 MHz to ≤2 GHz): < −40 dBc Sweep Capabilities

  • Step sweep: 1 to 10,000 steps with variable dwell time (1 ms to 99 seconds)

  • Switching time: < 15 ms + 1 ms/GHz or < 40 ms, whichever is less

  • Analog sweep: 1 MHz to full range, independently selected


Key Features



  • 1 kHz frequency resolution across full band; 0.1 Hz with Option 11

  • Excellent long-term stability with high-stability time base option

  • Ultra-low phase noise for precision signal simulation

  • Fast step switching for automated test sequences

  • Selectable sweep modes for frequency characterization


Typical Applications



  • RF component and subsystem testing

  • Signal source simulation for receiver analysis

  • Automated test equipment (ATE) integration

  • Phase noise and spectral purity measurement


Compatibility & Integration The 69069A accepts internal and external 10 MHz time base references, enabling synchronization with external frequency standards and integrated test systems.

Specifications

ParameterValue
Frequency Range0.01 to 40 GHz | Power Range (dBm): '+10 dBm (maximum leveled output)

Anritsu 69069A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 69069A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 69069A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 69069A price

This Anritsu 69069A is listed at $26,520. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 69069A calibration cost

NIST-traceable calibration for the Anritsu 69069A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents