Fluke 8050A-01 4.5 Digital Multimeter

The Fluke 8050A-01 is a 4.5-digit digital multimeter designed for accurate and reliable electrical measurements. It features a clear display, multiple measurement functions (voltage, current, resistance), and durable construction. Ideal for electronics troubleshooting, maintenance, and calibration applications.

Model
Fluke 8050A-01
Calibration
Available on request
Price
$79
Status
In stock
RFQ ref
8050A-01
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 8050A-01 is a 4.5-digit digital multimeter engineered for precision electrical measurements across DC voltage, AC voltage, current, resistance, and specialized functions including diode testing and dBm measurement. This portable instrument delivers 0.03% basic DC accuracy with true RMS capability from 20 Hz to 50 kHz, making it suitable for electronics troubleshooting, field service, and calibration work. The model 8050A-01 integrates rechargeable NiCad batteries providing 10 hours typical operating time, alongside AC line power operation (90–264 V, 47–440 Hz), enabling both cordless field deployment and stationary bench use. An automatic polarity indicator and overrange display enhance readability on the 4.5-digit LCD. Built-in transient protection rated to 6 kV, 10 microseconds, combined with overload protection and a 500 V dc maximum common mode voltage rating, safeguards the instrument against typical field hazards. Weighing 1.08 kg and measuring 22 cm × 6 cm × 25 cm, the meter fits standard equipment racks and portable kits.

Technical Specifications Measurement Functions & Ranges

DC Voltage: 10 µV to 1000 V

AC Voltage: 10 mV to 750 V true RMS (linear and dB)

DC Current: 10 nA to 2 A

AC Current: 10 µA to 2 A true RMS

Resistance: 10 mΩ to 20 MΩ

Conductance: Up to 100,000 MΩ (200 nS)

dBm Measurement: Selectable reference impedances Performance

Accuracy (DC): 0.03% basic

True RMS bandwidth: 20 Hz to 50 kHz

Operating temperature: 0°C to 50°C

Storage temperature: −40°C to +70°C (without batteries); −40°C to +50°C (with batteries)

Humidity: Up to 90% (0°C–35°C); up to 70% (35°C–50°C)

Temperature coefficient: <0.1× specification per °C (0°C–18°C, 28°C–50°C)

Calibration interval: 1 year Power & Protection

Rechargeable NiCad batteries: 10 hours typical operation; 14 hours recharge time (OFF position)

AC line power: 90–264 V, 47–440 Hz (field changeable)

Transient protection: 6 kV, 10 microseconds

Maximum common mode voltage: 500 V dc or peak ac

Key Features

Diode and transistor testing via forward voltage measurement

Relative reference function across all measurement modes

Automatic polarity indication and overrange display

True RMS AC measurement independent of waveform shape

Typical Applications Electronics diagnostics, field service maintenance, power supply validation, component characterization, and frequency-dependent AC measurements in industrial and laboratory environments.

Compatibility & Integration Model 8050A-01 includes rechargeable battery capability. Standard model 8050A operates on AC line power only. Dual input connectors (HI and COMMON) support standard test lead configurations.

Specifications

ParameterValue
Frequency Range20 Hz to 50 kHz (true RMS AC bandwidth) | Voltage / Current Range: DC voltage: 10 µV to 1000 V
AC voltage10 mV to 750 V
DC current10 nA to 2 A
AC current10 µA to 2 A

Fluke 8050A-01 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 8050A-01. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 8050A-01 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 8050A-01 price

This Fluke 8050A-01 is listed at $79. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 8050A-01 calibration cost

NIST-traceable calibration for the Fluke 8050A-01 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents