The Advantest R6451A is a 5.5-digit digital multimeter engineered for general-purpose electrical measurement across R&D, production, and field environments. This Japanese-manufactured instrument delivers true RMS AC measurements, frequency analysis, and resistance testing with 180 ppm + 5 digits accuracy on DC voltage and ±0.1% ± 6 digits on the 200 mΩ resistance range. The half-width 19" 2U form factor accommodates both benchtop and rack-mount deployment.


Technical Specifications

Measurement Capability

  • DC Voltage: 0.001 V to 700 V

  • AC Voltage: up to 700 V with true RMS processing

  • DC Current: up to 10 A

  • AC Current: up to 10 A with true RMS processing

  • Resistance: 2-wire and low-power modes; 200 Ω maximum (AC)

  • Frequency: 20 Hz to 100 kHz (AC voltage), 20 Hz to 5 kHz (AC current)

  • Continuity testing and analog bar graph display Performance Metrics

  • Display resolution: 199999 counts (5.5-digit)

  • Input impedance: ≥1000 MΩ (DC voltage ranges to 200 mV)

  • Sampling rates: 80 SPS (FAST), 10 SPS (MED), 2.5 SPS (SLOW)

  • Analog bar graph update rate: 80 times/second


Key Features



  • True RMS measurement for AC voltage and current eliminates errors from non-sinusoidal waveforms

  • High-speed analog bar graph enables real-time signal trend observation

  • Wide input impedance minimizes loading effects on sensitive circuits

  • Selectable sampling rates optimize response time and noise rejection

  • DC voltage accuracy of 180 ppm + 5 digits ensures precision in calibration-grade applications


Typical Applications



  • Component characterization and acceptance testing

  • Production line verification and troubleshooting

  • Field service and maintenance diagnostics

  • General electrical bench measurements


Compatibility & Integration Standard RS-232C interface; optional GPIB interface available. Universal power input: 90–250 V accommodates global facility requirements.

Specifications

ParameterValue
Frequency Range20 Hz to 100 kHz (AC voltage), 20 Hz to 5 kHz (AC current) | Voltage / Current Range: 0.001 V to 700 V DC/AC, 10 A AC, 10 A DC

Advantest R6451A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R6451A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest R6451A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Advantest R6451A price

This Advantest R6451A is listed at $879. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R6451A calibration cost

NIST-traceable calibration for the Advantest R6451A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →