HP / Agilent 83711B Synthesized CW Generator, 1 GHz to 20 GHz
The HP/Agilent 83711B is a synthesized CW generator that delivers continuous wave signals from 1 GHz to 20 GHz. It is ideal for testing microwave components and systems, providing stable and accurate signals for various applications.
- Model
- HP / Agilent 83711B
- Calibration
- Available on request
- Price
- $3,528
- Status
- In stock
- RFQ ref
- 83711B
This unit
The HP/Agilent 83711B is a synthesized continuous wave generator delivering stable, accurate microwave signals from 1 GHz to 20 GHz. Built for component and system characterization, it serves wireless communications, radar, and microwave test environments where signal purity and leveling precision are essential.
Technical Specifications Frequency & Resolution
Frequency range: 1 GHz to 20 GHz
Frequency resolution: 1 kHz (1 Hz with Option 1E8)
Time base stability: ±0.01 ppm (standard); high-stability option available Output Power
Maximum leveled output: +11 dBm (1–18 GHz, standard); +10 dBm (18–20 GHz, standard)
Minimum leveled output: -4 dBm (standard); -110 dBm (with Option 1E1)
Output level accuracy: ±1.0 dB from -4 dBm to maximum at 50 MHz–20 GHz
Output resolution: 0.01 dB
Output flatness: ±0.5 dB at levels ≥ -90 dBm Spectral Purity
Harmonics: < -50 dBc at levels < +6 dBm
Spurious: < -60 dBc
Sub-harmonics: None
SSB phase noise range: -107 to -65 dBc, with floor < -140 dBc/Hz below 500 MHz Modulation Capabilities
Pulse mode: up to 3 MHz repetition rate, 80 dB on/off ratio
Amplitude modulation: > 60 dB logarithmic depth; incidental AM < 5%
Frequency/phase modulation: ±10% accuracy at 100 kHz; < 1% harmonic distortion at 1 MHz peak deviation
FM/ΦM input impedance: 600 Ω nominal
Key Features
Fundamental oscillators with switched low-pass filters for < -55 dBc harmonic suppression
Multimode pulse generator: internal free-run, triggered, doublet, and gated burst modes
Simultaneous AM, FM/ΦM, and pulse modulation capability
0.01 dB output level resolution for fine-grained power control
Typical Applications Microwave component testing, system-level validation, RF subsystem characterization, and radar signal simulation requiring high spectral purity and precise leveling over extended frequency spans.
Compatibility & Integration SCPI command interface for automated test systems and instrument control.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 1 GHz to 20 GHz | Power Range (dBm): '-110 dBm to +11 dBm |
HP / Agilent 83711B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83711B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 83711B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP / Agilent 83711B price
This HP / Agilent 83711B is listed at $3,527.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 83711B calibration cost
NIST-traceable calibration for the HP / Agilent 83711B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →