Anritsu 69255A Synthesized Signal Generator, 0.05 – 26.5 GHz

Anritsu 69255A Synthesized Signal Generator,Provides precise CW signal generation from 0.05 to 26.5 GHz, ideal for bench and automated test systems in telecommunications and defense RF labs.

Model
Anritsu 69255A
Calibration
Available on request
Price
$14,570
Status
In stock
RFQ ref
69255A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 69255A is a synthesized signal generator delivering precise continuous-wave (CW) output from 0.05 GHz to 26.5 GHz. Engineered for telecommunications, defense, and RF laboratory applications, It has stable frequency generation with 1 kHz resolution and fast switching times suitable for automated test systems. The instrument supports multiple sweep modes, modulation capabilities, and can store up to 1000 non-sequential frequencies for phase-locked step sequencing via GPIB.


Technical Specifications

Frequency Range: 0.05 GHz to 26.5 GHz Frequency Resolution: 1 kHz (0.1 Hz with Option 11) Frequency Accuracy:

  • Aging: Less than 2 × 10⁻⁸ per day (standard); less than 5 × 10⁻¹⁰ per day (Option 16)

  • Temperature: Less than 2 × 10⁻⁸/°C over 0°C to 55°C (standard); less than 2 × 10⁻¹⁰/°C (Option 16) Phase Noise: Typical −100 dBc/Hz at 10 kHz offset from 10 GHz Output Power: −125 dBm to +17 dBm typical maximum Time Base: Internal high-stability option; external 10 MHz reference input; 10 MHz reference output at 0.5 V p-p into 50 Ω Switching Time: Typically less than 40 ms to within 1 kHz of final frequency


Key Features



  • Sweep width independently selectable from 1 MHz to full range

  • Dwell time per step: 1 ms to 99 seconds

  • Step sweep switching: Typically maximum 15 ms + 1 ms/GHz, or less than 40 ms (whichever is less)

  • Alternate sweep mode with independent power level assignment

  • Manual sweep with user-selectable step count or step size

  • AM, FM, and phase modulation support

  • List mode storing up to 1000 frequencies via GPIB (volatile memory)


Typical Applications Telecommunications testing, defense and aerospace system validation, RF component characterization, and integrated automated test environments.


Compatibility & Integration GPIB control interface; phase-locked operation with Wiltron 360B Vector Network Analyzer achieves sweep speeds as low as 8.5 ms/step (100 kHz resolution).

Specifications

ParameterValue
Frequency Range0.05 GHz to 26.5 GHz | Power Range (dBm): −125 dBm to +17 dBm | Voltage / Current Range: 0.5 V p-p (10 MHz reference output into 50 Ω)

Anritsu 69255A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 69255A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 69255A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 69255A price

This Anritsu 69255A is listed at $14,570. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 69255A calibration cost

NIST-traceable calibration for the Anritsu 69255A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents