Agilent / Keysight 86120D Multi-Wavelength Meter range: 700-1650 nm
Agilent / Keysight Wavelength Meters. Power Range (dBm): –40 dBm to –20 dBm (depending on wavelength band), Wavelength Range: 700 nm to 1650 nm (specified); 700 nm to 1700 nm (operating).
- Model
- Agilent / Keysight 86120D
- Calibration
- Available on request
- Price
- $10,834
- Status
- In stock
- RFQ ref
- 86120D
This unit
The Keysight 86120D Multi-Wavelength Meter is a precision optical measurement instrument covering 700 nm to 1650 nm, delivering absolute wavelength accuracy of ±1.5 ppm (typical ±1 ppm within 15 °C to 35 °C) with measurement cycle times under 0.6 seconds. The meter simultaneously measures individual laser lines and multiple signals across DWDM, component testing, and fiber characterization applications. It resolves spectral features to 15 GHz minimum line separation and handles linewidths to 10 GHz in narrowband mode.
Power measurement accuracy reaches ±0.6 dB with selectable measurement units in nm (vacuum or standard air), cm⁻¹, and THz.
Technical Specifications
- Wavelength Range: 700 nm – 1650 nm (specified); 700 nm – 1700 nm (operating)
- Absolute Wavelength Accuracy: ±1.5 ppm typical, ±1 ppm within 15 °C to 35 °C
- Measurement Cycle Time: Less than 0.6 seconds
- Maximum Linewidth (Narrowband Mode): 10 GHz
- Minimum Resolvable Line Separation: 15 GHz
- Power Accuracy: ±0.6 dB calibration accuracy at ±30 nm from 780 nm, 1310 nm, and 1550 nm
- Power Flatness: ±0.2 dB (1200 to 1600 nm)
- Power Linearity: ±0.3 dB (1200 to 1600 nm)
- Polarization Dependence: ±0.6 dB (1200 to 1600 nm)
- Sensitivity: –25 dBm (800–1200 nm); –40 dBm (1200–1600 nm); –30 dBm (1600–1650 nm); –20 dBm (700–900 nm)
- Selectivity: ≥100 GHz at 25 dB spacing; ≥25 GHz at 10 dB spacing
- Broadband Mode: Supported
Key Features
- Fast sub-0.6-second measurement cycles enable high-throughput production environments
- Supports both narrowband and broadband measurement modes
- Selectable output units: nm, cm⁻¹, THz
- Operating range extends to 1700 nm
Typical Applications
- DWDM system verification and channel power analysis
- Optical component testing and characterization
- Fiber laser and narrow-linewidth source measurements
- Multi-signal analysis across telecom and datacom wavelengths
Compatibility & Integration
- Connector options include FC/PC, FC/APC (narrow key), E-2000, SC, LC, MU, ST, and DIN (order separately)
- Operating temperature: 0 °C to +55 °C
- Humidity rated to 95% maximum
- Altitude operation to 2000 meters
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '-20 to -40 dBm (single line) |
| 10 to 18 dBm (multiple lines) | Voltage / Current Range | 100 V, 115 V, 230 V, 240 V (50 Hz, 60 Hz) | Wavelength Range: 700 nm to 1650 nm |
Agilent / Keysight 86120D — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 86120D. Calibration covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 86120D faults: interferometer alignment drift, reference etalon or HeNe laser end-of-life, InGaAs detector sensitivity loss, fiber input connector damage. Fizeau interferometer-based instruments (Agilent 86120B/86122A/C) most commonly develop interferometer alignment drift and InGaAs detector degradation over time. Burleigh WA-series scanning Fabry-Perot instruments most commonly fail due to reference HeNe laser end-of-life. Both types are fully repairable with post-repair wavelength accuracy verification.
Agilent / Keysight 86120D price
This Agilent / Keysight 86120D is listed at $10,834. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 86120D calibration cost
NIST-traceable calibration for the Agilent / Keysight 86120D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →