Advantest Q8326 480nm-1650nm Optical Wavelength Meter

Advantest Wavelength Meters. Frequency Range: 181 THz to 625 THz, Power Range (dBm): -30 dBm to +10 dBm, Voltage / Current Range: 48 Hz to 66 Hz, 90 V to 250 V AC.

Model
Advantest Q8326
Calibration
Available on request
Price
$4,500
Status
In stock
RFQ ref
Q8326
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest Q8326 is a precision optical wavelength meter for direct measurement of laser and LED wavelengths across the 480 nm to 1650 nm range. Using Michelson interference with a He-Ne reference laser, it delivers ±2 ppm ±1 count absolute accuracy and supports display resolution from 1 nm down to 0.0001 nm. The instrument provides continuous sampling at 5 Hz with 0.2 sec measurement time, plus moving-average and deviation functions for signal analysis.


Technical Specifications



  • Wavelength Range: 480 nm to 1650 nm

  • Wavelength Absolute Accuracy: ±2 ppm ±1 count

  • Wavelength Display Resolution: 1 nm to 0.0001 nm

  • Frequency Range: 181 THz to 625 THz

  • Maximum Input Level: +10 dBm

  • Level Sensitivity: −15 dBm (480–600 nm), −25 dBm (600–1650 nm), −30 dBm (1200–1650 nm)

  • Sampling Rate: 5 measurements/sec

  • Measurement Time: 0.2 sec

  • Input Voltage: 90 V to 250 V AC, 48 Hz to 66 Hz

  • Power Consumption: 60 VA or below

  • Laser Classification: Class 1


Key Features



  • Moving-average function with count of 10 for signal smoothing

  • Deviation measurement function referenced to standard values

  • GPIB interface for instrument control and data logging

  • Analog D/A conversion output standard

  • Dual-fiber input support: 9/125 µm SM and 50/125 µm GI

  • Horizontal-position operation with forced-air cooling


Typical Applications Optical communications systems, DWDM channel validation, laser oscillation-wavelength tuning and verification, LED spectral characterization, and frequency stability monitoring across the near-infrared and visible spectrum.


Compatibility & Integration GPIB connectivity enables integration into automated test environments. Analog output allows parallel data acquisition on external instrumentation. Requires 90–250 V AC supply, 48–66 Hz; operates to 2000 m altitude in pollution degree 2 environments with proper grounding.

Specifications

ParameterValue
Frequency Range181 THz to 625 THz | Power Range (dBm): '-30 dBm to +10 dBm | Voltage / Current Range: 48 Hz to 66 Hz, 90 V to 250 V AC | Wavelength Range: 480 nm to 1650 nm

Advantest Q8326 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest Q8326. Calibration covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest Q8326 faults: interferometer alignment drift, reference etalon or HeNe laser end-of-life, InGaAs detector sensitivity loss, fiber input connector damage. Fizeau interferometer-based instruments (Agilent 86120B/86122A/C) most commonly develop interferometer alignment drift and InGaAs detector degradation over time. Burleigh WA-series scanning Fabry-Perot instruments most commonly fail due to reference HeNe laser end-of-life. Both types are fully repairable with post-repair wavelength accuracy verification.

Advantest Q8326 price

This Advantest Q8326 is listed at $4,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest Q8326 calibration cost

NIST-traceable calibration for the Advantest Q8326 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →