Agilent / Keysight 86222B RF plug-in

The Agilent/Keysight 86222B is an RF plug-in module designed for use with compatible Agilent/Keysight test systems. This plug-in extends the capabilities of the test system, enabling it to generate and analyze RF signals within its specified frequency range. Ideal for signal generation and analysis in various RF applications.

Model
Agilent / Keysight 86222B
Calibration
Available on request
Price
$482
Status
In stock
RFQ ref
86222B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 86222B is an RF plug-in module designed for the 8620 series sweep oscillator mainframes. It delivers continuous swept-frequency coverage from 10 MHz to 2.4 GHz with calibrated power output from 0 to +13 dBm in 1 dB increments. The module maintains ±0.25 dB flatness across the entire frequency range and integrates a crystal marker system with selectable intervals of 1, 10, or 50 MHz for CRT display or RF signal monitoring.


Technical Specifications



  • Frequency Range: 10 MHz to 2.4 GHz (continuous sweep)

  • Calibrated Power Output: 0 to +13 dBm

  • Power Output Increments: 1 dB steps

  • Maximum Leveled Power: >20 mW (+13 dBm)

  • Internally Leveled Flatness: ±0.25 dB across full range

  • Residual AM (100 kHz bandwidth): <−50 dBc

  • Harmonic Spurious Signals: <−25 dBc at +13 dBm output power


Key Features



  • Crystal marker system with 1, 10, or 50 MHz interval selection

  • Markers displayable as intensified CRT spots or RF output amplitude dips

  • Optional rear-panel RF output with 0 to 70 dB step attenuator (Option 002/004)

  • Z-axis input for marker display synchronization

  • Marker output for external display control


Compatibility & Integration Designed exclusively for integration with Agilent/Keysight 8620 series sweep oscillator mainframes. Standard RF output connector; Option 002/004 provides rear-panel RF output with integrated step attenuator for enhanced signal path control.

Specifications

ParameterValue
Frequency Range10 MHz to 2.4 GHz | Power Range (dBm): 0 to +13 dBm

Agilent / Keysight 86222B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 86222B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight 86222B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Agilent / Keysight 86222B price

This Agilent / Keysight 86222B is listed at $482.2. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 86222B calibration cost

NIST-traceable calibration for the Agilent / Keysight 86222B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →