Analogic AN3100

Analogic Calibration Equipment. Accuracy: ±50 PPM of reading, Accuracy: ±150 PPM of reading.

Model
Analogic AN3100
Calibration
Available on request
Price
$650
Status
In stock
RFQ ref
AN3100
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Analogic AN3100 is a precision DC voltage standard for high-accuracy calibration and metrology applications. It generates stable, low-noise voltage outputs across dual ranges with exceptional linearity and long-term stability. The instrument delivers main output voltages to ±11.1110 V DC with 100 μV resolution and auxiliary outputs to ±111.110 mV DC with 1 μV resolution, supporting source currents to 50 mA and sink currents to 3 mA.


Absolute accuracy reaches ±50 PPM of reading ±50 μV on the main output, with temperature stability of ±2 PPM/°C and 60-day drift limited to ±15 PPM.


Technical Specifications

Output Ranges & Resolution

  • Main output: 0 to ±11.1110 V DC (100 μV resolution via five dialable decades and ±1 mV vernier)

  • Auxiliary output: 0 to ±111.110 mV DC (1 μV resolution)

  • MV output: Three-pin rear socket provides 1/100 of front panel voltage Accuracy & Stability

  • Main output absolute accuracy: ±50 PPM of reading, ±50 μV (includes 6-month stability and linearity)

  • Auxiliary output absolute accuracy: ±150 PPM of reading, ±0.5 μV (includes 6-month stability and linearity)

  • Long-term stability: ±15 PPM over 60 days

  • Linearity: ±25 PPM

  • Temperature coefficient: ±2 PPM/°C Output Characteristics

  • Main output impedance (DC): 10 mΩ maximum; (dynamic) L ≤ 10 μH, R ≤ 20 Ω

  • Auxiliary output impedance: 100 Ω

  • Noise (main output): (0.001% of reading + 50 μV) peak-to-peak

  • Settling time: ≤300 ms

  • Output isolation: Floatable to ±500 V DC above or below chassis ground Current Capability (Main Output)

  • Source: 0 to 50 mA, short-circuit proof

  • Sink: 0 to 3 mA

  • Load capacitance: unrestricted Thermal & Operational

  • Warmup: <10 minutes to rated accuracy; ±0.02% accuracy without warmup delay

  • Operating temperature: 0° to +60°C

  • Storage temperature: -25° to +85°C

  • Humidity: 0–85% RH non-condensing Power & Physical

  • Power: 117/234 VAC, 47–420 Hz, 10 W maximum (RF filter included)

  • Dimensions: 3.5" H × 8.5" W × 12" D (89 mm H × 216 mm W × 305 mm D)

  • Construction: Bench aluminum-alloy case with carrying handle; 19" rack adapter available

  • Recalibration interval: 6 months


Key Features



  • Five front-panel decade knobs for manual voltage selection

  • Dual output ranges accessible from front binding posts and rear terminals

  • Low output impedance and unrestricted capacitive loading

  • Noise floor independent of output voltage magnitude

  • Fast settling enables rapid test sequencing


Typical Applications



  • Precision calibration of digital multimeters and voltage standards

  • DC reference verification in metrology laboratories

  • Component testing requiring known reference voltages

  • Long-term stability monitoring of measurement instruments


Compatibility & Integration The AN3100 integrates into calibration workflows via standard front binding posts and rear panel connectors. Dual voltage outputs support simultaneous multi-channel reference applications. Floating output capability enables testing of isolated or differential circuits.

Specifications

ParameterValue
Voltage / Current Range0 to ±11.1110 V DC (main), 0 to ±111.110 mV DC (auxiliary)

Analogic AN3100 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Analogic AN3100. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Analogic AN3100 price

This Analogic AN3100 is listed at $650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Analogic AN3100 calibration cost

NIST-traceable calibration for the Analogic AN3100 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →