Fluke 742A-1 Resistance Standard

Fluke Calibration Equipment. Accuracy: ±2 ppm of nominal, Voltage: 0.5 V, Current: 500 mA.

Model
Fluke 742A-1
Calibration
Available on request
Price
$2,070
Status
In stock
RFQ ref
742A-1
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 742A-1 is a precision 1 Ω resistance standard engineered for high-accuracy calibration and verification in laboratory and field environments. This metrology-grade artifact delivers traceable, stable resistance values with no requirement for environmental controls such as oil or air baths, enabling on-site calibration work without infrastructure constraints.


Technical Specifications

Resistance & Accuracy

  • Nominal resistance: 1 Ω

  • Initial trim accuracy: ±2 ppm of nominal

  • Best 1-year specification: ±4 ppm

  • Temperature deviation (18°C to 28°C): 3.0 ppm maximum from 23°C reference Stability & Thermal Performance

  • Six-month stability: ±2.5 ppm

  • One-year stability: ±4 ppm

  • Retrace error (hysteresis): typically <2 ppm after 0°C to 40°C thermal cycling; negligible shift for 18°C–23°C–28°C cycles

  • Operating temperature range: 18°C to 28°C

  • Storage temperature range: 0°C to 40°C

  • Temperature coefficients (alpha and beta) referenced to 23°C; on-board label enables temperature correction Electrical Ratings

  • Maximum voltage: 0.5 V

  • Maximum current: 500 mA

  • Four-wire (Kelvin) configuration supported via dedicated binding posts for low-resistance measurement Connections & Interfaces

  • Current HI/LO binding posts

  • Sense HI/LO binding posts

  • Chassis ground binding post

  • Five-way low-thermal binding posts Physical Specifications

  • Dimensions: 86 mm H × 105 mm W × 127 mm D

  • Weight: 1.5 to 2 lbs (0.68 to 0.91 kg)

  • Construction: small and rugged form factor


Key Features



  • No special environmental conditioning required

  • Fluke Primary Standards Lab calibration with full traceability documentation

  • Rear panel label with measured value and temperature coefficients for field reference

  • Report of Calibration included with each unit


Typical Applications



  • Artifact calibration of precision calibrators and resistance bridges

  • Traceable resistance verification in accredited laboratories

  • On-site calibration and field standards work


Compatibility & Integration Ideally suited for artifact calibration of Fluke 5700A and 5720A Calibrators.

Specifications

ParameterValue
Voltage / Current Range0–0.5 V, 0–500 mA

Fluke 742A-1 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 742A-1. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 742A-1 price

This Fluke 742A-1 is listed at $2,070. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 742A-1 calibration cost

NIST-traceable calibration for the Fluke 742A-1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents