Fluke 732C DC Voltage Reference Standard
The Fluke 732C is a DC Voltage Reference Standard, a highly accurate and stable voltage source used for calibrating voltmeters and other voltage measurement instruments. It provides exceptional long-term stability and low temperature coefficient, ensuring reliable performance in demanding metrology applications.
- Model
- Fluke 732C
- Calibration
- Available on request
- Price
- $2,480
- Status
- In stock
- RFQ ref
- 732C
This unit
The Fluke 732C DC Voltage Reference Standard is a portable, battery-powered voltage source for disseminating and maintaining DC reference standards in primary and secondary calibration laboratories. It delivers three selectable output voltages - 10 V, 1 V, and 0.1 V DC - each traceable to national standards and the Fluke Calibration 10 V Josephson Array. Engineered for field portability and laboratory stability, the 732C combines long battery runtime with temperature-stable outputs and comprehensive power options for continuous or mobile operation.
Technical Specifications
Output Voltages & Stability- 10 V DC: ±2 µV/V per year (Base models); ±1 µV/V per year (Select models)
- 1 V DC: ±3 µV/V per year
- 0.1 V DC: ±9.8 µV/V per year
- Stability specifications apply at Tcal ±1 °C with IN CAL indicator active
- Outputs referenced to common VCOM binding post Temperature Performance
- 10 V output temperature coefficient: 0.04 µV/V-°C
- Accounts for drift when operating outside calibration temperature Power & Battery
- Internal battery: ≥72 hours minimum runtime at 23±5 °C with 0–0.1 mA total output current drain
- External DC input (rear panel): 12 V to 15 V DC, ≥300 mA capacity for indefinite operation
- AC line input: 100 V (90–110 V), 120 V (108–132 V), 220 V (198–242 V), 240 V (216–264 V) at 50/60 Hz
- AC line current at 120 V: typically 0.13 A
- Battery charging time: 10,000 MΩ to earth/chassis ground or AC line, shunted by <1000 pF
- All outputs short-circuit protected indefinitely
- 10 V output: rated for maximum 50 mA continuous at ≤220 V DC
Key Features
- Three independently accessible output voltage levels
- Selectable Select models offer 2× greater stability at 10 V output
- Long-term stability dominates uncertainty over 30+ day periods
- Field-deployable with minimal power dependencies
- High source impedance isolation for sensitive measurement environments
Typical Applications
- Primary and secondary reference standard maintenance
- Calibration laboratory voltage dissemination
- Portable on-site calibration verification
- DC voltage standard traceability chain validation
Compatibility & Integration The 732C accepts multiple AC line voltages worldwide and supports external 12–15 V DC supplies for laboratory or mobile benchtop integration. Binding post outputs enable direct connection to high-impedance calibration instruments and precision voltmeters.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 0.1 V DC outputs |
Fluke 732C — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 732C. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Fluke 732C price
This Fluke 732C is listed at $2,480. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 732C calibration cost
NIST-traceable calibration for the Fluke 732C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →