Anritsu TOSLK50A-20 – Coaxial calibration kit Type K(m) 50ohms

Anritsu Calibration Equipment. Frequency Range: DC to 20 GHz.

Model
Anritsu TOSLK50A-20
Calibration
Available on request
Price
$1,800
Status
In stock
RFQ ref
TOSLK50A-20
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu TOSLK50A-20 is a Type K(m) coaxial calibration kit engineered for precise RF and microwave measurements across DC to 20 GHz. This 50-ohm system delivers the calibration standards

Open, Short, Load, and optional Thru - required for SOLT (Short-Open-Load-Thru) calibration procedures on vector network analyzers and precision test instruments. The kit maintains exceptional return loss performance: ≥42 dB from DC to 10 GHz and ≥36 dB from 10 to 20 GHz on the load standard, ensuring accurate network characterization in both laboratory and field environments.


Technical Specifications



  • Frequency Range: DC to 20 GHz

  • Connector Type: Type K(m)

  • Impedance: 50 ohms

  • Load Return Loss: ≥42 dB (DC–10 GHz); ≥36 dB (10–20 GHz)

  • DC Resistance: 50 Ω ± 0.25 Ω

  • Physical Dimensions: 5.01 mm (Open and Short); 16.07 mm (Thru)

  • Operating Temperature: –10 °C to +55 °C

  • Storage Temperature: –51 °C to +71 °C

  • Weight: 3 lbs

  • Recommended Calibration Interval: 1 year


Key Features



  • Full SOLT calibration standards included with optional Thru element

  • Precision load standard with guaranteed return loss across the full frequency band

  • MIL-PRF-28800F Class 2 environmental specification for field durability

  • Traceable calibration available with ISO17025 and ANSI/NCSL Z540-1 certification


Typical Applications



  • Vector network analyzer (VNA) calibration

  • S-parameter measurement verification

  • Network characterization in RF and microwave test labs

  • Field calibration of portable test equipment


Compatibility & Integration Designed for Anritsu Vector Network Analyzers, including the MS46322A ShockLine VNA series. Type K connectors are compatible with 3.5 mm and SMA connector systems, enabling broader instrument integration across test benches.

Specifications

ParameterValue
Frequency RangeDC to 20 GHz

Anritsu TOSLK50A-20 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu TOSLK50A-20. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Anritsu TOSLK50A-20 price

This Anritsu TOSLK50A-20 is listed at $1,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu TOSLK50A-20 calibration cost

NIST-traceable calibration for the Anritsu TOSLK50A-20 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →