Tektronix DMM4050 Precision Multimeter, 6.5 Digit
Tektronix Laboratory Measurement Instruments. Accuracy: up to 0.0024% (1 year), Resolution: 100 nV minimum, Resolution: 100 pA minimum.
- Model
- Tektronix DMM4050
- Calibration
- Available on request
- Price
- $2,270
- Status
- In stock
- RFQ ref
- DMM4050
This unit
The Tektronix DMM4050 is a 6.5-digit precision benchtop multimeter engineered for research, development, and manufacturing environments requiring high-accuracy DC and AC measurements. This instrument consolidates multiple measurement functions into a single platform: DC voltage (100 mV to 1000 V), AC voltage to 1000 V, DC current (100 μA to 10 A), AC current to 10 A, resistance (10 Ω to 1 GΩ), frequency, period, capacitance, temperature, diode testing, and continuity. True RMS measurement capability handles both AC and AC + DC signals.
The dual display permits simultaneous monitoring of two parameters from a single test connection, eliminating setup reconfiguration.
Technical Specifications
Measurement Resolution & Accuracy- 6.5-digit resolution across all measurement types
- Basic DC voltage accuracy: up to 0.0024% (1 year)
- DC voltage resolution: 100 nV minimum
- DC current resolution: 100 pA minimum
- Resistance resolution: 10 μΩ minimum; 4-wire (2x4 Ω) technique supported
- Input impedance: 10 MΩ (default)
- Warm-up requirement: 1 hour minimum with Auto Zero enabled for specification compliance Measurement Functions
- Voltage: DC (100 mV–1000 V), AC (to 1000 V, valid >5% of range for sinewaves)
- Current: DC (100 μA–10 A), AC (to 10 A)
- Resistance: 10 Ω to 1 GΩ
- Frequency and period measurements
- Capacitance and temperature (DMM4050 only)
- Diode test and continuity Safety & Data Management
- Safety rating: CAT I 1000 V, CAT II 600 V
- Measurement statistics and histogram analysis
- TrendPlot™ paperless data recorder for trend analysis
Key Features
- Dual display for parallel measurement acquisition
- USB host port (front panel) for direct data and setup export to external storage
- Graphical analysis modes: histogram and TrendPlot™ for signal stability assessment
- Dedicated front-panel controls for rapid function access
Typical Applications Precision component characterization, circuit validation, thermal and capacitive measurements in electronics development and production testing.
Compatibility & Integration
- RS-232C (DTE 9-pin, 1200–230400 baud)
- IEEE 488.2 interface
- LAN: Ethernet 10/100Base-T with DHCP
- USB-to-RS-232 adapter cable included
- LabVIEW SignalExpress™ TE Limited Edition software included
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | AC current to 10 A, AC voltage to 1000 V, DC current 100 μA to 10 A, DC voltage 100 mV to 1000 V, resistance 10 Ω to 1 GΩ |
Tektronix DMM4050 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Tektronix DMM4050. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Tektronix DMM4050 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Tektronix DMM4050 price
This Tektronix DMM4050 is listed at $2,270. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Tektronix DMM4050 calibration cost
NIST-traceable calibration for the Tektronix DMM4050 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →