HP / Agilent 3456A 6 1/2 Digit Digital Multimeter
HP / Agilent Laboratory Measurement Instruments. Voltage: ** 0.1 V to 1000 V across five ranges, Voltage: ** 1 V to 1000 V across four ranges, Resolution: ** 100 nV at 48 readings per second (6 1/2 digits).
- Model
- HP / Agilent 3456A
- Calibration
- Available on request
- Price
- $886
- Status
- In stock
- RFQ ref
- 3456A
This unit
The HP/Agilent 3456A is a 6 1/2 digit digital multimeter engineered for precision measurement in calibration labs, R&D, and manufacturing environments. This microprocessor-based, fully guarded instrument delivers 100 nanovolts resolution at 48 readings per second and achieves ±0.0008% + 2 counts accuracy on the 10 V range over 24 hours at 23°C ±1°C. The 3456A combines high-speed burst capability - up to 330 readings per second - with ultra-low periodic measurement intervals down to one reading every fifteen minutes, making it equally suited to benchtop use and integration into automated test systems.
Technical Specifications
DC Voltage: 0.1 V to 1000 V across five ranges
AC RMS Voltage: 1 V to 1000 V across four ranges; true RMS measurements from 10 Hz to 250 kHz
Resistance: 100 Ω to 1 GΩ across eight ranges with 2-wire and 4-wire capability; 500 nA current source with 10 MΩ parallel resistance
Resolution: 100 nV at 48 readings per second (6 1/2 digits); up to 10 µV at 330 readings per second (3 1/2 or 4 1/2 digits)
Stability: 2 ppm over 24-hour period
Integration Time: Selectable 1, 10, or 100 power line cycles (PLC) for noise rejection
Temperature Coefficient: Specified as (% of reading + number of counts)/°C, varying with digit count and AC/DC ratios
Key Features
Offset Compensated Ohms (OCΩ) for enhanced resistance measurement accuracy
Selectable display digits: 2, 3, 4, 5, or 6
AUTO-ZERO feature for improved stability
Math functions include scaling, limit testing (Pass/Fail), nulling, percent error, dB, and dBm calculations
Program memory stores up to 1400 bytes of instrument command strings
Reading storage capacity: 350 readings, or 348 with 8-byte command string
Configurable settling time for measurement optimization
Typical Applications
Transfer standard measurements requiring high repeatability
Precision voltage and resistance measurements in metrology
High-speed automated test sequences
Long-duration periodic monitoring
Compatibility & Integration
HP-IB (IEEE-488) interface standard for remote programmability and system integration
Front panel indicators display HP-IB status during remote operation
Hardware scanner advance provides TTL signal upon measurement completion
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 20 Hz to 250 kHz | Voltage / Current Range: DC: 0.1 V to 1000 V |
| AC | 1 µV to 700 V |
HP / Agilent 3456A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3456A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 3456A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
HP / Agilent 3456A price
This HP / Agilent 3456A is listed at $885.58. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 3456A calibration cost
NIST-traceable calibration for the HP / Agilent 3456A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →