Agilent / Keysight 34460A Digital Multimeter, 6 Digit, Basic Truevolt
Agilent / Keysight Laboratory Measurement Instruments. Frequency Range: 3 Hz to 300 kHz, Voltage / Current Range: DCV: 100 mV to 1000 V; ACV: 100 mV to 750 V; DCI/ACI: 100 µA to 3 A.
- Model
- Agilent / Keysight 34460A
- Calibration
- Available on request
- Price
- $5,148
- Status
- In stock
- RFQ ref
- 34460A
This unit
The Keysight 34460A is a 6.5-digit digital multimeter built on Truevolt technology to deliver accurate measurements while minimizing noise and injected current effects. It combines a 4.3-inch color graphical display with a full suite of measurement functions
DC/AC voltage and current, resistance, frequency, capacitance, temperature, and diode testing - making it suitable for bench and field applications across electronics manufacturing, service, and research environments.
Technical Specifications
Voltage & Current Measurement- DC Voltage: 100 mV to 1000 V
- AC Voltage (True RMS): 100 mV to 750 V
- DC Current: 100 µA to 3 A
- AC Current (True RMS): 100 µA to 3 A
- Input Resistance: Selectable 10 MΩ or >10 GΩ on 0.1 V, 1 V, 10 V ranges; 10 MΩ ± 1% on 100 V and 1000 V ranges
- Input Bias Current: <30 pA at 25 °C Resistance & Impedance
- 2-Wire and 4-Wire Resistance: 100 Ω to 100 MΩ
- Continuity: Audible tone indicator
- Capacitance: 1 nF to 100 µF Frequency & Timing
- Frequency and Period: 3 Hz to 300 kHz Additional Functions
- Diode Test: 5 V
- Temperature Measurement: RTD/PT100 and thermistor support Accuracy & Performance
- Basic DC Voltage Accuracy (1-year): 75 ppm; ±(0.0075% of reading + 0.0005% of range)
- A/D Linearity: 0.0002% of reading + 0.0001% of range
- Resolution: 6.5 digits
- Maximum Reading Rate: 300 readings/s at 4.5 digits
- Temperature Coefficient: 0.0040 + 0.0060 per °C for DC voltage; 0.0040 + 0.0060 for 100 Ω resistance test current
- Input Protection: 1000 V on all ranges
Key Features
- 4.3-inch color display with number, histogram, bar chart, trend chart, math, and statistics modes
- 1,000-reading internal memory
- USB interface standard; optional LAN/LXI and GPIB connectivity
- Front-panel USB host port for mass storage configuration and data export
- ISO/IEC standards compliance (UL, CSA, CE)
- Operating temperature: 18–28 °C standard
Compatibility & Integration USB connectivity enables direct connection to PCs and peripherals. Optional interfaces support LAN/LXI and GPIB for integration into automated test systems. Front-panel USB host allows standalone configuration management and data logging.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 3 Hz to 300 kHz | Voltage / Current Range: DCV: 100 mV to 1000 V |
| ACV | 100 mV to 750 V |
| DCI/ACI | 100 µA to 3 A |
Agilent / Keysight 34460A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 34460A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 34460A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Agilent / Keysight 34460A price
This Agilent / Keysight 34460A is listed at $5,147.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 34460A calibration cost
NIST-traceable calibration for the Agilent / Keysight 34460A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →