Advantest R6561 Digital multimeter
Advantest Laboratory Measurement Instruments. Voltage / Current Range: 10 nV (micro-DC sensitivity), 20 mVpeak or less (Low Power mode), Sensitivity: 10 nV (micro-DC), Resolution: 1 μΩ (4-wire).
- Model
- Advantest R6561
- Calibration
- Available on request
- Price
- $2,579
- Status
- In stock
- RFQ ref
- R6561
This unit
The Advantest R6561 is a 6 1/2-digit digital multimeter engineered for precision DC voltage, micro-DC voltage, and resistance measurements in research and semiconductor applications. It delivers 10 nV sensitivity for micro-DC measurements and 1 μΩ resolution for resistance, supported by automatic offset cancellation and floating current source topology to eliminate thermal EMF and line resistance effects. Sampling rates reach 2,000 times per second with multi-sampling bulk output, enabling real-time data collection at 10 msec intervals in 6 1/2 digit mode.
Digital smoothing via moving average reduces noise without sacrificing measurement speed, while null function capability supports micro-resistance and offset voltage compensation.
Technical Specifications
- Display: 6 1/2 digits (maximum reading 1199999)
- DC Voltage sensitivity: 10 nV (micro-DC)
- Resistance resolution: 1 μΩ (4-wire)
- Sampling rate: 2,000 samples per second
- Data output interval: 10 msec (6 1/2 digit mode)
- Low Power mode terminal voltage: 20 mVpeak or less
- Temperature coefficient range: +18°C to +28°C (standard); 0°C to +18°C and +28°C to +40°C with +0.0001 adjustment to % reading
- 2-wire resistance accuracy: +0.2 Ω maximum additional error versus 4-wire measurement
Key Features
- Automatic offset cancellation and floating current source eliminate thermal EMF and parasitic resistance
- Multi-sampling bulk output mode for high-speed data acquisition
- Digital smoothing with moving average for low-signal reliability
- Null function for connection cable error measurement and offset voltage compensation
- Auto zero and auto calibration maintain accuracy with 1 hour calibration interval
- Measurement accuracy expressed as ± (% of reading + LS digit value)
Typical Applications
- Semiconductor device characterization
- Contact resistance and low-resistance component testing
- Superconductor and metal material measurements
- Basic research in electronic component evaluation
Compatibility & Integration Detailed accuracy specifications for 6 1/2 digit measurements are documented in the R6871E brochure.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 10 nV (micro-DC sensitivity), 20 mVpeak or less (Low Power mode) |
Advantest R6561 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest R6561. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Advantest R6561 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Advantest R6561 price
This Advantest R6561 is listed at $2,579. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest R6561 calibration cost
NIST-traceable calibration for the Advantest R6561 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →