Advantest R5372 Microwave frequency counter
The Advantest R5372 is a microwave frequency counter designed for accurate frequency measurements in the microwave range. It offers high resolution and sensitivity for demanding applications.
- Model
- Advantest R5372
- Calibration
- Available on request
- Price
- $1,479
- Status
- In stock
- RFQ ref
- R5372
This unit
The Advantest R5372 is a microwave frequency counter engineered for precise frequency measurements across the microwave spectrum. It employs Advantest's proprietary digital TRAHET system - combining transfer oscillator and heterodyne techniques - to deliver 1 Hz resolution at microwave frequencies while supporting pulse-modulated signal analysis. The instrument combines reciprocal counting for low-frequency precision with advanced heterodyne architecture for high-frequency accuracy, making it suitable for satellite communications, radar systems, and broadcast applications.
Technical Specifications
Frequency Measurement Range:- Input A: 10 mHz to 10 MHz (DC coupling); 10 Hz to 10 MHz (AC coupling)
- Input B: 500 MHz to 18 GHz
- Frequency resolution: 1 Hz in 1 second; user-selectable in decades from 0.1 Hz to 10 MHz Pulse-Modulated Carrier Measurement:
- Frequency range: 500 MHz to 18 GHz (Input B)
- Pulse width range: 100 ns to 0.1 s (internal sync); 50 ns to 0.1 s (external sync); minimum 0.5 µs
- Pulse width resolution: 10 ns
- Pulse repetition frequency: 10 Hz to 5 MHz
- FM tolerance: ±25 MHz (500 MHz–1.4 GHz manual); ±125 MHz or more (≥1.4 GHz manual); 10 MHz p-p (automatic, worst case) Input Specifications:
- Channel 1: 10 Hz to 550 MHz, 25 mV sensitivity, 5 V maximum input, 50 Ω impedance, AC coupling, x1/x20 attenuation
- Channel 2: 500 MHz to 18 GHz, 2.24 V sensitivity
- Maximum input: -20 dBm (500 MHz–18 GHz); +10 dBm (ATT AUTO); +20 dBm (ATT 20 dB) Time Base Stability:
- Standard: 1 × 10⁻⁷/yr (long-term); ±5 × 10⁻⁸ (temperature)
- Option 21: 5 × 10⁻⁹/day; ±5 × 10⁻⁸ (temperature)
- Option 22: 2 × 10⁻⁹/day; ±1 × 10⁻⁸ (temperature)
- Option 23: 5 × 10⁻¹⁰/day; ±5 × 10⁻⁹ (temperature)
- Time base output: 10 MHz, 1 Vp-p minimum, ~50 Ω impedance
- External standard input: 1, 2, 2.5, 5, or 10 MHz; 1–10 Vp-p; ~500 Ω impedance
Key Features
- Dual-channel architecture supports simultaneous low and microwave frequency measurements
- Digital TRAHET system enables high-resolution microwave analysis without external converters
- Pulse-width measurement with 10 ns resolution for radar and communications testing
- Selectable external frequency standards for traceability
- Attenuation options optimize signal conditioning across wide dynamic range
Typical Applications
- Satellite communication frequency verification
- Radar system carrier and modulation analysis
- Broadcast transmitter frequency stability monitoring
- Pulsed microwave signal characterization
Compatibility & Integration External frequency standard input accepts standard 10 MHz references via BNC connector, enabling integration with atomic clocks and frequency standards. Time base output provides 10 MHz reference for downstream instrumentation.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 mHz to 18 GHz (Input A: 10 mHz–10 MHz |
| Input B | 500 MHz–18 GHz) | Power Range (dBm): '-20 dBm to +20 dBm (with attenuation options) | Voltage / Current Range: Input: 1–10 Vp-p (external standard) |
| Output | 1 Vp-p min. (time base) |
Advantest R5372 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest R5372. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Advantest R5372 price
This Advantest R5372 is listed at $1,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest R5372 calibration cost
NIST-traceable calibration for the Advantest R5372 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →