Advantest R5373P Microwave frequency counter

Advantest Frequency Counters. Frequency Range: 10 mHz to 27 GHz, Power Range (dBm): –35 dBm to +20 dBm, Voltage / Current Range: 100–240 V AC, 50/60 Hz.

Model
Advantest R5373P
Calibration
Available on request
Price
$3,979
Status
In stock
RFQ ref
R5373P
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R5373P is a microwave frequency counter designed for precision measurement across 10 mHz to 27 GHz. It employs digital TRAHET technology - combining transfer and heterodyne techniques - to deliver high sensitivity and exceptional resolution. The instrument measures frequency, period, time interval, pulse width (minimum 0.5 µs), pulse repetition frequency (10 Hz to 5 MHz), carrier frequency of pulse-modulated signals, and FM deviation.


Resolution reaches 1 Hz in 1 second for microwave frequencies, with decade-selectable settings from 0.1 Hz to 10 MHz and maximum resolution to 0.1 mHz in specific modes. Timebase stability is 1.5 ppm, with accuracy of ±1 count plus time base accuracy. Measurement speed reaches 1000 measurements per second.


Technical Specifications



  • Frequency Range: 10 mHz to 27 GHz

  • Measurement Modes: Frequency, period, time interval, pulse width, pulse repetition frequency, carrier frequency of modulated signals, FM deviation

  • Resolution: 1 Hz (1 second gate, microwave), decade-selectable 0.1 Hz to 10 MHz, maximum 0.1 mHz

  • Accuracy: ±1 count ± time base accuracy ± residual stability (1/10 × measurement frequency in GHz, rms)

  • Timebase Stability: 1.5 ppm

  • Sensitivity: –35 dBm to +20 dBm

  • Measurement Speed: Up to 1000 measurements/second

  • FM Range: ±125 MHz (signals ≥1.4 GHz manual); ±25 MHz (500 MHz–1.4 GHz manual); 10 MHz p-p (automatic, worst case)

  • Power Supply: 100–240 V AC, 50/60 Hz


Key Features



  • Pulse width capability: minimum 0.5 µs

  • D-A analog output (–4.995 V to +4.995 V ±20 mV, 100 Ω max impedance)

  • 10 MHz timebase output (1 Vp-p min, ~50 Ω)

  • External frequency standard inputs: 1, 2, 2.5, 5, 10 MHz (1–10 Vp-p, ~500 Ω)

  • Compact form factor: 213 mm (W) × 88 mm (H) × 355 mm (D), 2.8 kg


Typical Applications Microwave communication systems, broadcast equipment, satellite communications, microwave and millimeter-wave circuit testing and calibration.


Compatibility & Integration



  • Interfaces: GPIB, RS-232C

  • Connectors: 14-pin TTL output (Amphenol 57-40140 equivalent), AUX input/output, BNC (timebase and external standard), SMA or N-type main input

Specifications

ParameterValue
Frequency Range10 mHz to 27 GHz | Power Range (dBm): –35 dBm to +20 dBm | Voltage / Current Range: 100–240 V AC, 50/60 Hz

Advantest R5373P — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R5373P. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Advantest R5373P price

This Advantest R5373P is listed at $3,979. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R5373P calibration cost

NIST-traceable calibration for the Advantest R5373P is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →