Advantest R5372P Microwave frequency counter

Advantest Frequency Counters. Frequency Range: 10 MHz to 18 GHz, Voltage / Current Range: 5 V maximum input (both channels).

Model
Advantest R5372P
Calibration
Available on request
Price
$1,479
Status
In stock
RFQ ref
R5372P
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R5372P is a dual-channel microwave frequency counter delivering precise measurements from 10 mHz to 18 GHz. Built on Advantest's digital TRAHET system - combining transfer oscillator, heterodyne, and reciprocal counting techniques - it excels at characterizing continuous-wave signals, pulse-modulated waveforms, and complex radar emissions. The instrument resolves 1 Hz in 1 second across microwave bands and captures pulse width and repetition frequency with 10 ns resolution.


Technical Specifications

Frequency Coverage & Channels

  • Overall range: 10 mHz to 18 GHz

  • Channel 1: 10 Hz to 550 MHz; 25 mV sensitivity; 5 V maximum input; 50 Ω impedance; ×1/×20 attenuation; AC coupling

  • Channel 2: 500 MHz to 18 GHz; 2.24 V sensitivity; 5 V maximum input; 50 Ω impedance; ×1/×20 attenuation; AC coupling

  • Reciprocal counting (A input): 10 mHz to 10 MHz with 10 ns resolution Timing & Stability

  • Time base stability: 0.0000001 /yr

  • Measurement throughput: 0.05 s

  • External time base reference: 10 MHz Computation & Analysis

  • Frequency offset display, difference count, frequency deviation (Δf), parts per million (ppm), and standard deviation

  • Maximum and minimum value holding

  • Arithmetic functions: addition, subtraction, multiplication, division

  • Digital comparator function

  • PCM error bit totalizing


Key Features



  • Simultaneous two-channel input for comparative measurements

  • Burst wave measurement capability

  • Radar-specific metrics for aircraft, harbor, river, and fire prevention applications

  • Totalizing functions for repetitive phenomena

  • AC-coupled inputs protect against DC offset drift


Typical Applications



  • Microwave and RF component characterization

  • Pulsed radar signal analysis and verification

  • Pulse width and duty cycle measurement

  • Carrier frequency tracking in modulated systems

  • Frequency deviation monitoring and trending


Compatibility & Integration External 10 MHz time base reference input accommodates synchronization to primary frequency standards. Operates in horizontal position with forced-air cooling; maintain 10 cm minimum clearance around ventilation vents.

Specifications

ParameterValue
Frequency Range10 MHz to 18 GHz | Voltage / Current Range: 5 V maximum input (both channels)

Advantest R5372P — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R5372P. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Advantest R5372P price

This Advantest R5372P is listed at $1,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R5372P calibration cost

NIST-traceable calibration for the Advantest R5372P is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →