Advantest R5372P Microwave frequency counter
Advantest Frequency Counters. Frequency Range: 10 MHz to 18 GHz, Voltage / Current Range: 5 V maximum input (both channels).
- Model
- Advantest R5372P
- Calibration
- Available on request
- Price
- $1,479
- Status
- In stock
- RFQ ref
- R5372P
This unit
The Advantest R5372P is a dual-channel microwave frequency counter delivering precise measurements from 10 mHz to 18 GHz. Built on Advantest's digital TRAHET system - combining transfer oscillator, heterodyne, and reciprocal counting techniques - it excels at characterizing continuous-wave signals, pulse-modulated waveforms, and complex radar emissions. The instrument resolves 1 Hz in 1 second across microwave bands and captures pulse width and repetition frequency with 10 ns resolution.
Technical Specifications
Frequency Coverage & Channels- Overall range: 10 mHz to 18 GHz
- Channel 1: 10 Hz to 550 MHz; 25 mV sensitivity; 5 V maximum input; 50 Ω impedance; ×1/×20 attenuation; AC coupling
- Channel 2: 500 MHz to 18 GHz; 2.24 V sensitivity; 5 V maximum input; 50 Ω impedance; ×1/×20 attenuation; AC coupling
- Reciprocal counting (A input): 10 mHz to 10 MHz with 10 ns resolution Timing & Stability
- Time base stability: 0.0000001 /yr
- Measurement throughput: 0.05 s
- External time base reference: 10 MHz Computation & Analysis
- Frequency offset display, difference count, frequency deviation (Δf), parts per million (ppm), and standard deviation
- Maximum and minimum value holding
- Arithmetic functions: addition, subtraction, multiplication, division
- Digital comparator function
- PCM error bit totalizing
Key Features
- Simultaneous two-channel input for comparative measurements
- Burst wave measurement capability
- Radar-specific metrics for aircraft, harbor, river, and fire prevention applications
- Totalizing functions for repetitive phenomena
- AC-coupled inputs protect against DC offset drift
Typical Applications
- Microwave and RF component characterization
- Pulsed radar signal analysis and verification
- Pulse width and duty cycle measurement
- Carrier frequency tracking in modulated systems
- Frequency deviation monitoring and trending
Compatibility & Integration External 10 MHz time base reference input accommodates synchronization to primary frequency standards. Operates in horizontal position with forced-air cooling; maintain 10 cm minimum clearance around ventilation vents.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 18 GHz | Voltage / Current Range: 5 V maximum input (both channels) |
Advantest R5372P — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest R5372P. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Advantest R5372P price
This Advantest R5372P is listed at $1,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest R5372P calibration cost
NIST-traceable calibration for the Advantest R5372P is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →