Anritsu 69275A Synthesized Signal Generator, 0.5 – 50.0 GHz
Anritsu 69275A Synthesized Signal Generator,Covers 0.5 to 50 GHz frequency range with low phase noise and consistent amplitude control. Used for precision testing of wideband systems and high-frequency signal chains.
- Model
- Anritsu 69275A
- Calibration
- Available on request
- Price
- $25,670
- Status
- In stock
- RFQ ref
- 69275A
This unit
The Anritsu 69275A is a synthesized signal generator covering 0.5 GHz to 50.0 GHz, engineered for precision testing of wideband RF and microwave systems. It delivers low phase noise performance with consistent amplitude control across its frequency range, making it suitable for component analysis, signal simulation, and automated test equipment integration.
Technical Specifications
- Frequency Range: 0.5 GHz to 50.0 GHz
- Phase Noise: Ultra-low single sideband (SSB) phase noise across the frequency band
- Amplitude Control: Consistent amplitude control enabling precise power level setting
- Output Power: Maximum +17 dBm; minimum –125 dBm
- Frequency Resolution: 0.1 Hz available as an option
- Step Sweep Switching Time: Typically less than 15 ms plus additional time per GHz, maximum 40 ms
- Maximum Step Count: Up to 10,000 steps supported
Key Features
- Internal AM, FM, and phase modulation (φM)
- Pulse modulation with external or internal pulse generator control
- Doublet, triplet, and quadruplet pulse generation for RADAR blind spot testing
- User-downloaded complex modulation and arbitrary waveform generation
- Step sweep with phase-locked frequency steps and selectable dwell time per step
- Alternate sweep mode between two selected ranges with independent power levels
- Manual sweep mode with phase-locked frequency adjustment
- Adjustable step size and step count
Typical Applications
- Component characterization and analysis
- Wideband signal simulation
- Automated test equipment (ATE) systems
- RF and microwave system testing
- RADAR signal generation and validation
Compatibility & Integration The 69275A integrates into demanding RF test environments requiring both frequency agility and modulation flexibility. Its modulation architecture supports internal signal generation and user-defined waveform injection for complex simulation scenarios.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.5 GHz to 50.0 GHz | Power Range (dBm): '-125 dBm to +17 dBm |
Anritsu 69275A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu 69275A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu 69275A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Anritsu 69275A price
This Anritsu 69275A is listed at $25,670. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu 69275A calibration cost
NIST-traceable calibration for the Anritsu 69275A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →