HP / Agilent 83595A RF plug-in provides a 10 MHz to 26.5 GHz broadband coaxial swept
The HP/Agilent 83595A is an RF plug-in designed for broadband coaxial swept measurements. It operates within a frequency range of 10 MHz to 26.5 GHz, offering versatile performance for various RF applications. Ideal for testing and characterization of RF components and systems.
- Model
- HP / Agilent 83595A
- Calibration
- Available on request
- Price
- $1,746
- Status
- In stock
- RFQ ref
- 83595A
This unit
The HP/Agilent 83595A is a broadband coaxial swept frequency source plug-in for the Agilent 8350B mainframe, delivering 10 MHz to 26.5 GHz coverage across five bands. This RF source excels in scalar network analysis, local oscillator applications, and standalone signal generation, combining wide frequency sweep capability with narrowband precision tuning.
Technical Specifications Frequency Coverage
Range: 10 MHz to 26.5 GHz (five bands: 10 MHz–2.4 GHz, 2.4–7 GHz, 7–13.5 GHz, 13.5–20 GHz, 20–26.5 GHz)
CW accuracy: ±5 MHz (Bands 0–1); ±10 MHz (Band 2–3); ±12 MHz (Band 4)
Sweep accuracy: ±15 to ±50 MHz depending on band and sweep width
Frequency marker accuracy: ±15 to ±50 MHz, ±0.5% of sweep width (band-dependent)
Temperature stability: ±200 to ±800 MHz/°C (typical, band-dependent) Output Power
Maximum leveled power: 10 mW (Bands 0–3); 2.5 mW (Band 4)
Power accuracy: ±1.3 to ±1.8 dB (band-dependent)
Minimum settable power: −5 dBm standard; −60 dBm with Option 002
Maximum output level: +4 dBm
Resolution: 0.1 dB displayed; 0.01 dB programmable
Harmonics and subharmonics: <−25 dBc (Bands 0–3); <−20 dBc (Band 4) Sweep Performance
Minimum sweep time: 10 ms (single band); 30 ms (full band) Modulation Capability
External AM: 100 kHz response, 1 dB/V sensitivity, 15 dB range
External FM: ±75 MHz (DC–100 Hz); ±7 MHz (100 Hz–1 MHz); ±5 MHz (1–2 MHz); ±1 MHz (2–10 MHz); −20 MHz/V sensitivity
Phase lock: −6 MHz/V sensitivity
External pulse modulation: TTL compatible; 15 nsec rise/fall time (10 MHz–2.5 GHz)
Key Features
Single-plug coverage from 10 MHz through 26.5 GHz eliminates band-switching complexity
Fine frequency resolution and CW accuracy support precision measurement and calibration tasks
Integrated leveling maintains constant output across broadband sweeps
Multiple modulation modes
AM, FM, phase lock, and pulse - enable diverse signal conditioning
Low harmonic content <−20 dBc ensures clean spectral characteristics
Typical Applications
Scalar network analysis across S-parameters
Down-converter local oscillator for superheterodyne receivers
Stimulus source for broadband RF system characterization
Signal generation for component and subsystem testing
Compatibility & Integration Operates exclusively as a plug-in module with the Agilent 8350B sweep oscillator mainframe, which provides power, control interface, and display functions.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 26.5 GHz | Power Range (dBm): '-5 dBm to +4 dBm |
HP / Agilent 83595A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83595A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 83595A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP / Agilent 83595A price
This HP / Agilent 83595A is listed at $1,745.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 83595A calibration cost
NIST-traceable calibration for the HP / Agilent 83595A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →