Keysight (Agilent) 83599A RF Plug-in for the Agilent 8350B, 10 MHz to 50 GHz
The Keysight (Agilent) 83599A is an RF plug-in module designed for use with the Agilent 8350B sweep oscillator. It operates over a frequency range of 10 MHz to 50 GHz, providing a broad bandwidth for various RF and microwave applications. This plug-in enhances the functionality of the 8350B by extending its frequency capabilities and offering precise signal generation.
- Model
- Keysight / Agilent 83599A
- Calibration
- Available on request
- Price
- $5,200
- Status
- In stock
- RFQ ref
- 83599A
This unit
The Keysight (Agilent) 83599A RF Plug-in extends the Agilent 8350B sweep oscillator mainframe across 10 MHz to 50 GHz, delivering precise signal generation for RF and microwave measurements. This module provides frequency reference outputs, wideband power control, and modulation capabilities essential for network analysis, component characterization, and local oscillator applications in coaxial systems.
Technical Specifications
Frequency Performance- Frequency range: 10 MHz to 50 GHz
- CW frequency accuracy: Better than ±5 to ±25 MHz depending on frequency of operation
- Frequency reference output: Switch selectable at 0.5 V/GHz (0.01 to 38 GHz) or 0.25 V/GHz (0.01 to 50 GHz) with ±25 mV accuracy below 2.4 GHz and ±100 mV above 2.4 GHz Output Power Characteristics
- Typical output power: +10 dBm to 20 GHz, +3 dBm to 40 GHz, 0 dBm to 50 GHz
- High power mode (2.4 to 20 GHz): +15 dBm
- Minimum settable power: -12 dBm
- Power sweep range: Greater than 12 dB (up to 22 dB below 20 GHz)
- Power slope range: 0–5 dB/GHz Harmonic and Spurious Performance
- Harmonic suppression greater than 45 dBc from 1.5 to 20 GHz, greater than 40 dBc to 40 GHz, greater than 35 dBc to 50 GHz
- Spurious signals above 50 GHz: <–35 dBc typical Modulation Capabilities
- Pulse input: TTL compatible with <50 nsec rise/fall time typical
- Minimum RF pulse width: <1.5 µsec (internally leveled) or 60 dB typical
- External AM: 100 kHz frequency response, 15 dB control range, 1 dB/V sensitivity
- Internal square-wave modulation: 1 kHz or 27.8 kHz
- External FM: ±75 MHz deviation (DC to 100 Hz), ±7 MHz (100 Hz to 1 MHz), ±1 MHz (1 to 2 MHz) Physical and Electrical
- RF output connector: 2.4 mm male
- Power consumption: 375 V-A including RF plug-in
- Net weight: 6.5 kg
Key Features
- Broadband 10 MHz to 50 GHz coverage in single plug-in module
- 2.4 mm connectors ensure rugged, repeatable performance across full frequency range
- Dual-mode frequency reference output with switchable sensitivity
- High power mode extends output level to +15 dBm in 2.4–20 GHz band
- Sophisticated harmonic suppression maintains signal purity across decade-spanning bandwidth
Typical Applications
- Scalar network analysis and component testing to 50 GHz in coaxial configurations
- Local oscillator signal generation for heterodyne and superheterodyne systems
- Broadband RF/microwave measurements requiring frequency and power sweeping
Compatibility & Integration Designed exclusively for the Agilent 8350B sweep oscillator mainframe. 2.4 mm connectors integrate with Agilent scalar network analyzer accessories (8757C/E) and other instrumentation, enabling complete 10 MHz to 50 GHz coaxial measurement systems.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 50 GHz | Power Range (dBm): '-12 dBm to +15 dBm | Voltage / Current Range: 375 V-A |
Keysight / Agilent 83599A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent 83599A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keysight / Agilent 83599A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Keysight / Agilent 83599A price
This Keysight / Agilent 83599A is listed at $5,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keysight / Agilent 83599A calibration cost
NIST-traceable calibration for the Keysight / Agilent 83599A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →