Instek GFG-8219A Function Generator

The Instek GFG-8219A is a function generator that delivers stable and precise waveforms for a variety of testing and measurement applications. It features a frequency range up to 20 MHz, multiple waveform types (sine, square, triangle, pulse, and ramp), and versatile modulation capabilities (AM/FM/sweep). Its user-friendly interface ensures ease of operation, while its solid design guarantees reliability in both laboratory and field environments.

Model
Instek GFG-8219A
Calibration
Available on request
Price
$245
Status
In stock
RFQ ref
GFG-8219A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Instek GFG-8219A is a versatile analog function generator delivering precision waveforms across 0.3 Hz to 3 MHz for audio response testing, vibration analysis, servo evaluation, and ultrasonic applications. This instrument combines a main signal output exceeding 10 Vpp into 50 Ω with a built-in 6-digit frequency counter spanning 5 Hz to 150 MHz, offering engineers integrated signal generation and measurement in a single platform.

Technical Specifications Frequency Range & Output

0.3 Hz to 3 MHz across 7 ranges

Main output: >10 Vpp into 50 Ω ±10%

DC offset: −5 V to +5 V

Output impedance: 50 Ω ±10% Waveforms

Sine, triangle, square, ramp, TTL, and CMOS

Sine distortion: <1% (0.3 Hz to 200 kHz); <0.3 dB flatness (0.3 Hz to 300 kHz); 98% (0.3 Hz to 100 kHz); >95% (100 kHz to 3 MHz)

Square symmetry: ±2% (0.3 Hz to 100 kHz); rise/fall time 3 Vpp, <25 ns rise/fall, 20 TTL loads fan-out

CMOS: 4 Vpp ±1 Vpp to 14.5 Vpp ±0.5 Vpp (adjustable), <120 ns rise/fall Built-in Counter

6-digit display; 5 Hz to 150 MHz range

High resolution measurement of internal or external signals

External input: ≤30 V AC

Key Features

6-digit LED display for frequency readout

External signal measurement capability (counter input)

Continuously adjustable duty cycle with polarity inversion

Dual output capability for simultaneous testing

Typical Applications

Audio and vibration system characterization

Servo loop testing and evaluation

Ultrasonic device excitation

Frequency response measurement

Compatibility & Integration All connectors are BNC: main output, GCV, VCF input, external modulation, counter input, TTL, and CMOS outputs. Power requirement: 100–240 V AC.

Specifications

ParameterValue
Frequency Range0.3 Hz to 3 MHz | Voltage / Current Range: −5 V to +5 V DC offset

Instek GFG-8219A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Instek GFG-8219A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Instek GFG-8219A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

Instek GFG-8219A price

This Instek GFG-8219A is listed at $245. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Instek GFG-8219A calibration cost

NIST-traceable calibration for the Instek GFG-8219A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents