Instek GFG-8219A Function Generator
The Instek GFG-8219A is a function generator that delivers stable and precise waveforms for a variety of testing and measurement applications. It features a frequency range up to 20 MHz, multiple waveform types (sine, square, triangle, pulse, and ramp), and versatile modulation capabilities (AM/FM/sweep). Its user-friendly interface ensures ease of operation, while its solid design guarantees reliability in both laboratory and field environments.
- Model
- Instek GFG-8219A
- Calibration
- Available on request
- Price
- $245
- Status
- In stock
- RFQ ref
- GFG-8219A
This unit
The Instek GFG-8219A is a versatile analog function generator delivering precision waveforms across 0.3 Hz to 3 MHz for audio response testing, vibration analysis, servo evaluation, and ultrasonic applications. This instrument combines a main signal output exceeding 10 Vpp into 50 Ω with a built-in 6-digit frequency counter spanning 5 Hz to 150 MHz, offering engineers integrated signal generation and measurement in a single platform.
Technical Specifications Frequency Range & Output
0.3 Hz to 3 MHz across 7 ranges
Main output: >10 Vpp into 50 Ω ±10%
DC offset: −5 V to +5 V
Output impedance: 50 Ω ±10% Waveforms
Sine, triangle, square, ramp, TTL, and CMOS
Sine distortion: <1% (0.3 Hz to 200 kHz); <0.3 dB flatness (0.3 Hz to 300 kHz); 98% (0.3 Hz to 100 kHz); >95% (100 kHz to 3 MHz)
Square symmetry: ±2% (0.3 Hz to 100 kHz); rise/fall time 3 Vpp, <25 ns rise/fall, 20 TTL loads fan-out
CMOS: 4 Vpp ±1 Vpp to 14.5 Vpp ±0.5 Vpp (adjustable), <120 ns rise/fall Built-in Counter
6-digit display; 5 Hz to 150 MHz range
High resolution measurement of internal or external signals
External input: ≤30 V AC
Key Features
6-digit LED display for frequency readout
External signal measurement capability (counter input)
Continuously adjustable duty cycle with polarity inversion
Dual output capability for simultaneous testing
Typical Applications
Audio and vibration system characterization
Servo loop testing and evaluation
Ultrasonic device excitation
Frequency response measurement
Compatibility & Integration All connectors are BNC: main output, GCV, VCF input, external modulation, counter input, TTL, and CMOS outputs. Power requirement: 100–240 V AC.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.3 Hz to 3 MHz | Voltage / Current Range: −5 V to +5 V DC offset |
Instek GFG-8219A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Instek GFG-8219A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Instek GFG-8219A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.
Instek GFG-8219A price
This Instek GFG-8219A is listed at $245. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Instek GFG-8219A calibration cost
NIST-traceable calibration for the Instek GFG-8219A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →