HP / Agilent 8165A 50 MHZ PULSE/FUNCTION GENERATOR

HP / Agilent Function Generators. Resolution: 1 µHz (1 to 9.999 mHz range), Accuracy: ±0.001%.

Model
HP / Agilent 8165A
Calibration
Available on request
Price
$385
Status
In stock
RFQ ref
8165A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 8165A is a 50 MHz programmable pulse and function generator delivering precise, multi-waveform signal generation across 1.000 mHz to 50.00 MHz. Built for laboratory and field testing, it generates sine, square, and triangle waveforms to 50.00 MHz, plus pulse and ramp outputs to 19.99 MHz with selectable duty cycles and symmetry. Frequency resolution reaches 1 µHz in the millihertz band, with ±0.001% accuracy and ±1 × 10⁻⁴ synthesizer stability - enabling tight tolerance measurements in component characterization, circuit validation, and system integration workflows.

Technical Specifications Frequency Performance

Range: 1.000 mHz to 50.00 MHz

Resolution: 1 µHz (1 to 9.999 mHz range)

Accuracy: ±0.001%

Stability: ±1 × 10⁻⁴ (synthesizer) Waveform Generation

Sine, Square, Triangle: DC to 50.00 MHz (50% duty cycle for square)

Pulse, Ramp: DC to 19.99 MHz (20%, 80% symmetry options)

Haversine/Havertriangle: Available via special option Output Parameters

Amplitude into 50 Ω: 10.0 mVpp to 10.0 Vpp

Amplitude into 1 kΩ: 2.00 Vpp to 20.0 Vpp

DC Offset into 50 Ω: ±0 to ±5.00 V

DC Offset into 1 kΩ: ±0 to ±10.0 V

Independent amplitude and offset control within ±10 V window

Source Impedance: 50 Ω ±1% or 1 kΩ ±10% (selectable) Signal Quality

Sine THD (fundamental to 1 MHz): 38 dB

Harmonic distortion (fundamental >1 MHz): ≤ -30 dBc

Key Features

Operating modes: Normal, VCO (external), Triggered, Gated, Burst, FM, AM

Sweep and Amplitude Modulation (Option 002)

Trigger, gate, and counted burst capabilities

Non-volatile storage: Ten complete parameter sets with battery backup

HP-IB interface: Full programmability via front panel or remote command

Typical Applications Component testing, circuit characterization, frequency response analysis, modulation studies, and system integration validation.

Compatibility & Integration HP-IB control enables integration into automated test benches and remote measurement systems. Rear panel connector option (Option 003) accommodates fixed-installation configurations. Operating temperature minimum: -10 °C.

Specifications

ParameterValue
Frequency Range1.000 mHz to 50.00 MHz | Voltage / Current Range: 10.0 mVpp to 10.0 Vpp (50 Ω load)

HP / Agilent 8165A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 8165A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 8165A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

HP / Agilent 8165A price

This HP / Agilent 8165A is listed at $385. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 8165A calibration cost

NIST-traceable calibration for the HP / Agilent 8165A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents