Stanford Research DS335 – Synthesized Function Generator

The Stanford Research Systems DS335 is a synthesized function generator that delivers high-performance functionality. It is designed to produce a wide range of waveforms with exceptional precision and stability. Ideal for electronics testing, research, and development, the DS335 ensures accurate and reliable signal generation.

Model
Stanford Research Systems DS335
Calibration
Available on request
Price
$430
Status
In stock
RFQ ref
DS335
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Stanford Research Systems DS335 is a synthesized function generator built on Direct Digital Synthesis (DDS) architecture for precision signal generation across benchtop and automated test environments. It delivers sine, square, ramp, triangle, and Gaussian white noise waveforms with exceptional spectral purity and stability, making it suitable for electronics testing, research, and development applications requiring accurate waveform synthesis.


Technical Specifications

Frequency and Waveform Generation

  • Frequency range: 1 µHz to 3.1 MHz

  • Frequency resolution: 1 µHz

  • Sine output: up to 3.1 MHz with spurious response <-65 dBc (≤1 MHz) and <-55 dBc (1–3.1 MHz)

  • Square wave: up to 3.1 MHz with rise/fall time <15 ns ± 5 ns (10%–90%)

  • Ramp and triangle: up to 10 kHz with ±0.1% linearity

  • Gaussian white noise: 3.5 MHz bandwidth

  • Harmonic distortion: <-60 dBc (DC–100 kHz), <-50 dBc (100 kHz–1 MHz), <-40 dBc (1–3 MHz)

  • Phase noise: <-60 dBc (30 kHz band) Amplitude and Offset

  • Output range: 50 mVpp to 10 Vpp (50 Ω); 100 mVpp to 20 Vpp (high-Z load)

  • DC offset: ±5 VDC (50 Ω); ±10 VDC (high-Z load)

  • Amplitude resolution: 3 digits

  • Amplitude accuracy: 0.1 dB (sine) Modulation and Sweeps

  • FSK: internal (50 kHz max) and external (1 MHz TTL)

  • Frequency sweeps: linear and logarithmic, phase-continuous

  • Sweep rate: 0.01 Hz to 1 kHz

  • Sweep span: full range (linear), 6 decades (logarithmic)

  • Bidirectional sweep capability with rear-panel output Timebase

  • Standard accuracy: ±5 ppm (20–30 °C)

  • Optional TCXO: 2 ppm stability and aging (20–50 °C)


Key Features



  • Non-volatile memory stores nine instrument configurations

  • Optional RS-232 and GPIB interfaces with full remote control

  • Compact benchtop form factor: 8.5" W × 3.5" H × 13" D, 8 lbs

  • Low power consumption: 22 W

  • Universal AC input: 100/120/220/240 VAC, 50/60 Hz


Typical Applications



  • Circuit characterization and validation

  • Component testing and device qualification

  • Frequency response measurements

  • Modulation and sweep testing in development labs

Specifications

ParameterValue
Frequency Range0.1 Hz to 3 MHz | Voltage / Current Range: 47-63 Hz, Output: 1 mVp-p to 10 Vp-p
DC Offset±5 V
Power100-120 VAC or 200-240 VAC

Stanford Research Systems DS335 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Stanford Research Systems DS335. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Stanford Research Systems DS335 faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

Stanford Research Systems DS335 price

This Stanford Research Systems DS335 is listed at $430. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Stanford Research Systems DS335 calibration cost

NIST-traceable calibration for the Stanford Research Systems DS335 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →