Fluke PM5138A Programmable Function Generator, 0.1 mHz to 10 MHz

The Fluke PM5138A is a programmable function generator capable of producing a wide range of waveforms from 0.1 mHz to 10 MHz. It offers versatile signal generation for various testing and measurement applications, including sine, square, triangle, and pulse waveforms. Its programmable interface allows for automated testing and integration into automated systems.

Model
Fluke PM5138A
Calibration
Available on request
Price
$830
Status
In stock
RFQ ref
PM5138A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke PM5138A is a programmable function generator delivering precision waveform synthesis from 0.1 mHz to 10 MHz. It generates sine, square, triangle, ramp, pulse, sawtooth, and noise waveforms with output up to 40 Vpp across all modes. User-defined arbitrary waveforms are created through the AnyWave™ software package and stored in 24 dedicated memory slots; nine additional slots preserve instrument settings for rapid recall.


Technical Specifications



  • Frequency range: 0.1 mHz to 10 MHz

  • Output voltage: Up to 40 Vpp (all waveforms)

  • Sine wave distortion: <0.1%

  • Output impedance: Selectable 50 Ω or 600 Ω

  • Arbitrary waveform memory: 24 slots

  • Setting memory: 9 slots

  • Modulation/trigger source frequency: 1 mHz to 100 kHz at 0.1% accuracy

  • Sweep range: 20 Hz to 20 MHz (linear or logarithmic)

  • Power supply: 100–240 VAC, 50–60 Hz, 80 VA

  • Dimensions: 215 mm × 89 mm × 360 mm

  • Weight: 2.3 kg

  • Display: Large backlit LCD with waveform preview


Key Features



  • Modulation modes: AM, FM, PSK, FSK, PWM, gate, burst, and sweep (linear/logarithmic)

  • Three sweep modes: sweep and flyback, sweep and hold, sweep up and down

  • Independently programmable sweep parameters: fstart, fstop, time, lin/log selection, and mode

  • Trigger modes: Burst, external, or internal

  • External synchronization: 10 MHz reference input

  • Optional GPIB or RS-232 interfaces for system integration


Typical Applications Electronics testing, signal analysis, system development, and transducer simulation benefit from the PM5138A's programmability and modulation flexibility. Its arbitrary waveform capability and memory storage enable automated test sequences and rapid parameter switching.


Compatibility & Integration AnyWave™ software enables creation and management of arbitrary waveforms. Standard output connectors and optional GPIB/RS-232 interfaces facilitate integration into automated test systems.

Specifications

ParameterValue
Frequency Range0.1 MHz to 10 MHz | Voltage / Current Range: 100–240 VAC

Fluke PM5138A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke PM5138A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke PM5138A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

Fluke PM5138A price

This Fluke PM5138A is listed at $830. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke PM5138A calibration cost

NIST-traceable calibration for the Fluke PM5138A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents