BK Precision 2160A 60MHz Dual Trace Oscilloscope
The BK Precision 2160A is a 10 MHz function generator that delivers high performance and versatility. It offers sine, square, triangle, and pulse waveforms with excellent signal quality. Ideal for education, hobbyists, and service applications.
- Model
- BK Precision 2160A
- Calibration
- Available on request
- Price
- $650
- Status
- In stock
- RFQ ref
- 2160A
This unit
The BK Precision 2160A is a 60 MHz, dual-channel analog oscilloscope that offers a balance of performance and cost-effectiveness, making it suitable for a variety of electronics applications including product design, assembly lines, repair and servicing, and electrical engineering education. It features a built-in component tester for in-circuit troubleshooting.
Technical Specifications * Bandwidth: 60 MHz
- Channels: 2
- Vertical Sensitivity: * 5 mV/div (full bandwidth) * 1 mV/div (with X5 MAG)
- Time Base Ranges: 23 calibrated ranges for both the main and delayed time bases
- Sweep Speed: 0.1 µs/div
- Accelerating Voltage: 12 kV
- CRT Type: 6-inch rectangular with internal graticule
- Input Impedance: 1 MΩ +/- 2% in parallel with 25 pF +/- 10 pF
- Triggering: * ALT triggering * Hold-off function * TV synchronization capability (with high- and low-frequency rejection) * AUTO, NORM, TV-V, TV-H coupling
- Component Tester: * Tests resistors, capacitors, inductors, and semiconductors * Test Voltage: 6 Vrms maximum (open) * Test Current: 11 mA maximum (shorted) * Test Frequency: Line frequency (60 Hz in USA)
- Signal Delay Time: Available
- Z-Axis Input: Available
- Single Sweep: Available
- Sweep Output: TTL level for synchronization of external equipment
- Intensity Modulation Input: TTL level, intensity increases with more positive levels; Input Impedance: 50 kΩ; Usable Frequency Range: DC to 5 MHz
- Maximum Input Voltage: 400 V (nominal), 800 V p-p
- Rise Time: 5.8 ns
Physical and Environmental * Power Requirements: 110/120/220/240 V ±10%, 50/60 Hz
- Dimensions (H x W x D): 12.76 x 15.68 x 5.2 inches (324 x 398 x 132 mm)
- Weight: 16.75 lbs (7.6 kg)
- Operating Temperature: 32˚ to 122˚F (0˚ to +50˚C)
- Storage Temperature: -22˚ to 158˚F (-30˚ to +70˚C)
Included Accessories * Instruction Manual
- Two PR 33A x1/x10 Probes or equivalent
- AC Power Cord
- Spare Fuse Why Choose Aumictech for the BK Precision 2160A? At Aumictech, we specialize in supplying test and measurement equipment. Whether you need reliable analog oscilloscopes for detailed signal analysis, versatile component testers for efficient troubleshooting, or durable equipment for educational and service applications, our team ensures the BK Precision 2160A delivers maximum performance for your specific engineering and laboratory requirements.
BK Precision 2160A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the BK Precision 2160A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common BK Precision 2160A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.
BK Precision 2160A price
This BK Precision 2160A is listed at $650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
BK Precision 2160A calibration cost
NIST-traceable calibration for the BK Precision 2160A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →