HP / Agilent 16193A Small side electrode SMD test fixture

HP / Agilent Calibration Equipment. Frequency Range: DC to 2 GHz, Voltage: 40 V.

Model
HP / Agilent 16193A
Calibration
Available on request
Price
$8,072
Status
In stock
RFQ ref
16193A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 16193A is a precision test fixture engineered for impedance measurement of surface-mount devices with small side electrodes. It delivers repeatable, accurate connections across SMD sizes from 0.5 mm to 3.2 mm, supporting quality control, component evaluation, and R&D characterization in laboratory and manufacturing environments.


Technical Specifications



  • DUT Size Range: 0.5 mm to 3.2 mm

  • Supported SMD Formats: 1005(mm)/0402(inch), 1608(mm)/0603(inch), 2012(mm)/0805(inch), 3216(mm)/1206(inch); Option 010 available for EIA/EIAJ sized devices

  • Frequency Range: DC to 2 GHz

  • Maximum DC Bias Voltage: 40 V

  • Operating Temperature: −55 °C to +85 °C

  • Operating Humidity: 15 % to 95 % RH (wet bulb <40 °C)

  • Dimensions: 150 mm (W) × 70 mm (H) × 80 mm (D)

  • Weight: 500 g


Key Features



  • Direct connection to 4191A, 4291B, and E4991A impedance analyzers

  • Wide frequency coverage from DC through 2 GHz enables characterization across multiple measurement regimes

  • Temperature-stable operation across −55 °C to +85 °C supports both benchtop and chamber-based testing

  • Compact form factor minimizes test station footprint


Typical Applications



  • SMD impedance and capacitance measurement

  • In-process quality verification of passives and RF components

  • Material characterization and dielectric loss evaluation

  • Component reliability and aging studies


Compatibility & Integration Direct connection: 4191A, 4291B, E4991A With adapters and options:

4395A, 4396A/B (via 43961A with Option 010)

4195A (via 41951A)

4294A (via 42942A RF adapter)

4284A1 (via 16085B RF adapter)

4194A (via 16099A RF adapter with 41941A)

Specifications

ParameterValue
Frequency RangeDC to 2 GHz | Voltage / Current Range: 40 V maximum DC bias

HP / Agilent 16193A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 16193A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

HP / Agilent 16193A price

This HP / Agilent 16193A is listed at $8,071.9. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 16193A calibration cost

NIST-traceable calibration for the HP / Agilent 16193A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents