HP / Agilent 16193A Small side electrode SMD test fixture
HP / Agilent Calibration Equipment. Frequency Range: DC to 2 GHz, Voltage: 40 V.
- Model
- HP / Agilent 16193A
- Calibration
- Available on request
- Price
- $8,072
- Status
- In stock
- RFQ ref
- 16193A
This unit
The HP/Agilent 16193A is a precision test fixture engineered for impedance measurement of surface-mount devices with small side electrodes. It delivers repeatable, accurate connections across SMD sizes from 0.5 mm to 3.2 mm, supporting quality control, component evaluation, and R&D characterization in laboratory and manufacturing environments.
Technical Specifications
- DUT Size Range: 0.5 mm to 3.2 mm
- Supported SMD Formats: 1005(mm)/0402(inch), 1608(mm)/0603(inch), 2012(mm)/0805(inch), 3216(mm)/1206(inch); Option 010 available for EIA/EIAJ sized devices
- Frequency Range: DC to 2 GHz
- Maximum DC Bias Voltage: 40 V
- Operating Temperature: −55 °C to +85 °C
- Operating Humidity: 15 % to 95 % RH (wet bulb <40 °C)
- Dimensions: 150 mm (W) × 70 mm (H) × 80 mm (D)
- Weight: 500 g
Key Features
- Direct connection to 4191A, 4291B, and E4991A impedance analyzers
- Wide frequency coverage from DC through 2 GHz enables characterization across multiple measurement regimes
- Temperature-stable operation across −55 °C to +85 °C supports both benchtop and chamber-based testing
- Compact form factor minimizes test station footprint
Typical Applications
- SMD impedance and capacitance measurement
- In-process quality verification of passives and RF components
- Material characterization and dielectric loss evaluation
- Component reliability and aging studies
Compatibility & Integration Direct connection: 4191A, 4291B, E4991A With adapters and options:
4395A, 4396A/B (via 43961A with Option 010)
4195A (via 41951A)
4294A (via 42942A RF adapter)
4284A1 (via 16085B RF adapter)
4194A (via 16099A RF adapter with 41941A)
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 2 GHz | Voltage / Current Range: 40 V maximum DC bias |
HP / Agilent 16193A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 16193A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 16193A price
This HP / Agilent 16193A is listed at $8,071.9. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 16193A calibration cost
NIST-traceable calibration for the HP / Agilent 16193A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →