HP / Agilent 16380C Capacitance Standard Set – 0.01uF to 10uF

The HP/Agilent 16380C is a capacitance standard set that includes a range of precision capacitors from 0.01uF to 10uF. These standards are used for calibrating capacitance meters and other impedance measuring instruments. The set provides accurate and stable capacitance values for reliable measurements.

Model
HP / Agilent 16380C
Calibration
Available on request
Price
$2,400
Status
In stock
RFQ ref
16380C
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 16380C Capacitance Standard Set is a precision calibration instrument for verifying capacitance measurement accuracy in LCR meters and impedance analyzers. This three-capacitor set - with optional fourth element - spans 0.01 µF to 10 µF and delivers exceptional long-term stability across standard laboratory environments.


Technical Specifications

Capacitance Range: 0.01 µF to 10 µF Standard Capacitors Included:

  • 0.01 µF (Model 16385A)

  • 0.1 µF (Model 16386A)

  • 1 µF (Model 16387A) Optional Capacitor:

  • 10 µF (Model 16388A) Accuracy (Nominal):

  • 0.01 µF, 0.1 µF, 1 µF: ±0.10%

  • 10 µF (optional): ±0.05%

  • Calibration accuracy: ±0.01% Stability: ±50 to ±300 ppm/year depending on capacitor value Dissipation Factor: ≤0.0004 to 0.0007 depending on capacitor value; <50 ppm/year drift Temperature Coefficient: ±10 ppm/°C Operating Temperature Range: 0°C to 50°C Connector: 4-terminal pair, BNC Dimensions: 142(W) × 88(H) × 112(D) mm Weight (with case and 3 capacitors): Approximately 7.0 kg


Key Features



  • High capacitance stability virtually unaffected by environmental temperature fluctuations

  • 4-terminal pair configuration for direct instrument connection

  • Adaptable to two-, three-, and five-terminal configurations

  • Low dissipation factor across all standard capacitor values


Typical Applications Performance verification and certification of 4-terminal pair LCR meters and impedance analyzers over the 0.01 µF to 10 µF measurement range. Suitable for both laboratory and industrial calibration workflows.


Compatibility & Integration Compatible with: 4194A, 4263A/B, 4268A, 4278A, 4284A, 4288A, 4294A, E4980A, E4980AL, E4981A, E4990A Calibration: Recommended annually; more frequent intervals advised for extreme temperature environments.

HP / Agilent 16380C — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 16380C. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

HP / Agilent 16380C price

This HP / Agilent 16380C is listed at $2,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 16380C calibration cost

NIST-traceable calibration for the HP / Agilent 16380C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →