Keithley 175A Autoranging Multimeter

The Keithley 175A Autoranging Multimeter is a reliable and versatile instrument for electrical measurements. It features automatic ranging for ease of use and provides accurate readings of voltage, current, and resistance. Ideal for electronics testing, troubleshooting, and general-purpose measurements.

Model
Keithley 175A
Calibration
Available on request
Price
$75
Status
In stock
RFQ ref
175A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 175A is a 4.5-digit autoranging digital multimeter engineered for precision DC and AC measurements across voltage, current, and resistance. Built for both benchtop and portable field use, it delivers True RMS AC readings, manual or automatic range selection, and a 100-point data logger with Min/Max hold capability. The backlit LCD display and relative measurement functions make it practical for troubleshooting and verification tasks in manufacturing, service, and design environments.


Technical Specifications

Display & Interface

  • 4.5-digit LCD, 0.5 inch character height

  • Electroluminescent backlight for low-light operation

  • Polarity, function, range, and status indicators DC Voltage

  • Range: 10 µV to 1000 V

  • Basic accuracy: 0.03%

  • Input impedance: 11 MΩ (200 mV and 2 V ranges); 10 MΩ (20 V, 200 V, 1000 V ranges)

  • Normal mode rejection: >60 dB at 50 Hz, 60 Hz ±0.15%

  • Settling time: 1 second to within 1 count

  • Maximum input: 1000 V DC or peak AC (300 V rms continuous; <10 seconds per minute for 200 mV and 2 V) True RMS AC Voltage

  • Range: 10 µV to 750 V

  • Bandwidth: 100 kHz typical; 300 kHz at 3 dB

  • Crest factor: 3

  • Input impedance: 11 MΩ || <75 pF (200 mV, 2 V); 10 MΩ || <75 pF (20 V, 200 V, 1000 V)

  • Settling time: 2 seconds to within 15 counts

  • Temperature coefficient: ±(0.1 × applicable accuracy)/°C; ±(0.07% + 2)/°C for 50 Hz–10 kHz

  • Maximum input: 750 V rms, 1000 V peak (300 V rms continuous; <10 seconds per minute for 200 mV) DC Current

  • Range: 10 nA to 10 A

  • Overload protection: 2 A fuse (250 V) on mA input; 20 A for 15 seconds (unfused) on 10 A input

  • Burden voltage: 0.3 V (200 µA–20 mA, 10 A ranges); 0.8 V (2000 mA range)

  • Settling time: 1 second to within 1 count (mA ranges); 2 seconds to within 15 counts (10 A range) True RMS AC Current

  • Range: 10 nA to 2 A

  • Overload protection: 2 A fuse (250 V) on mA input; 20 A for 15 seconds (unfused) on 10 A input

  • Settling time: 2 seconds to within 15 counts

  • Derating: 0.15% rdg./amp above 5 A for self-heating Resistance

  • Range: 10 mΩ to 200 MΩ

  • Basic accuracy: 0.05% + 2 counts (200 Ω range)

  • Open-circuit voltage: +5 V

  • Settling time: 2 seconds to within 1 count on range dB Mode

  • Reference: 600 Ω

  • Accuracy: ±(0.02 dB + 1 count) above -78 dBm

  • Resolution: 0.01 dB above 5% of range


Key Features



  • Autoranging and manual range selection

  • 100-point data logger with Min/Max hold

  • Relative measurement function

  • True RMS AC measurement for harmonically distorted waveforms


Typical Applications



  • Benchtop verification and component testing

  • Field service and troubleshooting

  • Process monitoring and quality assurance

  • Audio and telecommunications measurement


Compatibility & Integration Portable form factor supports both stationary lab use and mobile field deployment.

Specifications

ParameterValue
Frequency RangeDC to 100 kHz (AC voltage)
DC to 300 kHz at 3 dB | Power Range (dBm)'-78 dBm and above | Voltage / Current Range: DC Voltage: 10 µV to 1000 V
AC Voltage10 µV to 750 V
DC Current10 nA to 10 A
AC Current10 nA to 2 A
Resistance10 mΩ to 200 MΩ

Keithley 175A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 175A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 175A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Keithley 175A price

This Keithley 175A is listed at $75. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 175A calibration cost

NIST-traceable calibration for the Keithley 175A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →