Bruel & Kjaer 2690-0S-WH3345 Nexus Microphone Conditioner

Bruel & Kjaer Signal Conditioning Modules. Voltage: 0 V or 200 V.

Model
Bruel & Kjaer 2690-0S-WH3345
Calibration
Available on request
Price
$2,400
RFQ ref
2690-0S-WH3345
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Brüel & Kjær 2690-0S-WH3345 Nexus Microphone Conditioner is a modular signal conditioning mainframe engineered for precision acoustic and vibration measurement in field and laboratory environments. The NEXUS architecture supports one to four independent input channels, accommodating condenser microphones, CCLD accelerometers, charge transducers, hydrophones, force transducers, and sound intensity probes within a single reconfigurable unit. This flexibility enables users to build custom measurement configurations without replacing hardware.

Technical Specifications Input Architecture

Modular NEXUS mainframe; up to four independent channels per unit

Condenser microphone inputs via 7-pin LEMO connectors with floating topology for EMI rejection

CCLD and charge transducer support with current and voltage overload detection

Sound intensity probe channels with IEC 61043 Class 1 and ANSI S1.9–1996 Class 1 compliance Microphone & Preamplifier Supply

Selectable polarization voltage: 0 V or 200 V

Preamplifier supply: ±14 V or ±40 V (user-selectable)

Current overload detection on all microphone channels CCLD Transducer Support

Constant current output: 4 mA or 10 mA

8 V DC tacho probe supply on TNC inner screen Signal Conditioning

Adjustable gain: -20 dB to 80 dB with automatic calibration storage

Low-pass filters: 0.1, 1, 3, 10, 22.4, 30, 100 kHz at 40 dB/decade

High-pass filters: 0.1, 1, 10, 20 Hz (20 Hz/80 dB/decade for 20 Hz)

A-weighting filter standard; B-, C-, D-weighting available on request

Intensity-specific 20 Hz/40 dB/decade high-pass filter

Optional single and double integration filters; user-defined filters on request Overload Management Multi-stage detection: transducer current (CCLD and microphone), transducer voltage, common-mode input, signal, and common-mode output. Status indication via front-panel LEDs and RS-232 interface.

Key Features

Floating microphone inputs eliminate ground-loop interference

Integrated reference generator capability

Front-panel overload status indication with RS-232 reporting

Tool-free module reconfiguration

Typical Applications Automotive testing, environmental acoustics, structural vibration analysis, sound intensity surveys, and general-purpose signal conditioning for transducer-based measurement systems.

Compatibility & Integration RS-232 interface for remote overload monitoring and system control. Accepts standard Brüel & Kjær NEXUS input modules and accessories.

Specifications

ParameterValue
Voltage / Current Range0 V or 200 V (microphone polarization)

Bruel & Kjaer 2690-0S-WH3345 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Bruel & Kjaer 2690-0S-WH3345. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Bruel & Kjaer 2690-0S-WH3345 price

This Bruel & Kjaer 2690-0S-WH3345 is listed at $2,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Bruel & Kjaer 2690-0S-WH3345 calibration cost

NIST-traceable calibration for the Bruel & Kjaer 2690-0S-WH3345 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →