Keithley 2790-HH J Sourcemeter Switch System

Keithley Embedded Test Systems. Current: 50µA at rated accuracy, Voltage: 5.5V ±10%, Current: <.

Model
Keithley 2790-HH J
Calibration
Available on request
Price
$10,880
Status
In stock
RFQ ref
2790-HH J
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 2790-HH SourceMeter Switch System combines high-voltage sourcing, precision measurement, and multi-channel switching in a compact modular instrument. Engineered for automated functional testing, it delivers programmable voltage (50V to 500V) and current (0 to 50mA) sourcing with integrated DMM capability and switching matrices supporting up to 40 channels. Ideal for automotive ignition systems, connector validation, and complex harness characterization where simultaneous source and measure operations are required.


Technical Specifications

Sourcing Performance

  • Voltage Source: 50V to 500V programmable, 100mV resolution, 0.5% + 0.1V accuracy (2-year), 250ms settling time (50V to 500V step)

  • Current Source: 0 to 50mA programmable, 10µA resolution, 0.06% + 10µA accuracy (2-year), 1ms settling time

  • Maximum Output Current: 50µA at rated accuracy; <1mA typical short-circuit; 1mA safety limit (impedance-limited)

  • Compliance Voltage: 5.5V ±10%

  • Temperature Coefficient: Voltage (0.001% + 0.005V)/°C; Current specified across 0–18°C and 28–40°C

  • Dry Circuit Clamp: 20mV ±10%, source current ≤1mA Measurement Capabilities

  • 6-1/2 digit DMM with dual resistance measurement methods: constant-current for 10GΩ // <400pF or 10MΩ ±1% (100mV–10V ranges); 10MΩ ±1% (100V, 1000V ranges)

  • Input Bias Current: <100pA at 23°C

  • A-D Linearity: 2.0 ppm reading + 1.0 ppm range

  • Input Protection: 1000V front, 300V rear (7702 card) Switching Architecture

  • Up to 40 channels maximum

  • Supported modules: 7702 (40-ch general-purpose multiplexer), 7751 (high-voltage source/switch), 7752 (low-voltage current-source-only), 7753 (1MΩ high-voltage source/switch) Physical & Environmental

  • Mainframe: 89mm H × 213mm W × 370mm D or 104mm H × 238mm W × 370mm D

  • Supply: 100/120/220/240V ±10%, -5%; 50/60Hz

  • Lithium battery-backed memory (3-year retention at 23°C)

  • 2-year calibration cycle


Key Features



  • Modular switching matrix accommodates single or dual test stands

  • Impedance-limited safety design protects DUTs in dry-circuit applications

  • Selectable input impedance for low-noise voltage measurement

  • Mixed sourcing modes enable device and signal testing in one platform


Typical Applications



  • Automotive airbag inflator and seatbelt pre-tensioner ignition testing

  • Wiring harness and connector functional validation

  • High-voltage component characterization and burn-in screening


Compatibility & Integration Accepts 7700-series switching cards for flexible channel configuration and mixed measurement/sourcing requirements across automotive, industrial controls, and component reliability workflows.

Specifications

ParameterValue
Voltage / Current Range0 to 50mA, 50V to 500V

Keithley 2790-HH J — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 2790-HH J. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 2790-HH J faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.

Keithley 2790-HH J price

This Keithley 2790-HH J is listed at $10,880. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 2790-HH J calibration cost

NIST-traceable calibration for the Keithley 2790-HH J is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents