Krohn-Hite 3323
Krohn-Hite Signal Conditioning Modules. Channels: ** 2 (isolated, Frequency Range: ** 0.01 Hz to 99.9 kHz (low-pass, Voltage: ** ±7 V peak (0 dB gain to 500 kHz).
- Model
- Krohn-Hite 3323
- Calibration
- Available on request
- Price
- $650
- RFQ ref
- 3323
This unit
The Krohn-Hite 3323 is a digitally tuned, dual-channel variable filter delivering precision signal conditioning across 0.01 Hz to 99.9 kHz. Each isolated channel operates independently with selectable low-pass, high-pass, band-pass, and band-reject configurations. Engineers configure cutoff frequencies via three decade switches and a six-position multiplier, achieving 24 dB/octave attenuation per channel or 48 dB/octave when cascaded. The instrument delivers maximum attenuation exceeding 80 dB to 100 kHz, with pass-band gains of 0 dB or 20 dB and output impedance of 50 ohms.
Technical Specifications
Channels: 2 (isolated, independent power supplies and connectors)
Cutoff Frequency Range: 0.01 Hz to 99.9 kHz (low-pass, high-pass, band-reject)
Band-Reject Null Operation: 0.01 Hz to 10 kHz
High-Pass Upper 3 dB Point: Approximately 1 MHz
Attenuation Slope: 24 dB/octave per channel; 48 dB/octave (cascaded same mode)
Maximum Attenuation: >80 dB (to 100 kHz); 60 dB at 1 MHz
Pass-Band Gain: 0 dB (unity) or 20 dB (gain of 10)
Maximum Output Voltage: ±7 V peak (0 dB gain to 500 kHz); ±0.7 V peak (20 dB gain to 500 kHz); ±3 V peak (20 dB gain at 1 MHz, open circuit)
Maximum Output Current: ±70 mA peak (to 500 kHz); 30 mA peak (at 1 MHz)
Output Impedance: 50 ohms
Hum and Noise: <0.5 mV RMS (100 kHz bandwidth); 2 mV RMS (10 MHz bandwidth); 2–5 mV RMS (X100 band, high-pass mode)
Output DC Stability: ±1 mV/hour; ±1 mV/°C
Distortion: <0.1% (typical across range)
Calibration Accuracy: ±2%
Filter Response: Four-pole Butterworth (maximally flat) or four-pole RC (damped)
Maximum AC Input Voltage: ±1 V peak (0 dB gain); ±0.7 V peak (20 dB gain)
Maximum DC Input Voltage: ±100 V
Input Impedance: 10 ohms
Key Features
Dual isolated channels enable parallel or series cascading for band-reject or band-pass operation
Selectable RC or Butterworth response optimizes for time-domain or frequency-domain performance
Decade-switch tuning with multiplier provides direct frequency setting without lookup tables
Low output impedance (50 ohms) drives high-impedance loads and distribution networks
Typical Applications
Audio and vibration signal conditioning
Precision measurement preprocessing
Multi-channel test signal filtering
Transient-optimized filtering (RC mode) or flat-passband filtering (Butterworth mode)
Compatibility & Integration Dual isolated channels with independent connectors integrate into rack systems and bench setups. ±100 V DC maximum input rating accommodates transducer outputs and signal sources across industrial and laboratory environments.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 50-400 Hz | Voltage / Current Range: 108-132 VAC input |
Krohn-Hite 3323 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Krohn-Hite 3323. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Krohn-Hite 3323 price
This Krohn-Hite 3323 is listed at $650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Krohn-Hite 3323 calibration cost
NIST-traceable calibration for the Krohn-Hite 3323 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →