HP / Agilent 3435A 3-1/2 DMM AUTORG

The HP/Agilent 3435A is a 3-1/2 digit, autoranging digital multimeter designed for general-purpose electronic measurements. It offers reliable performance and ease of use for voltage, current, and resistance measurements.

Model
HP / Agilent 3435A
Calibration
Available on request
Price
$92
Status
In stock
RFQ ref
3435A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 3435A is a 3-1/2 digit autoranging digital multimeter engineered for general-purpose electronic test and measurement. This five-function instrument delivers DC voltage, AC voltage, DC current, AC current, and resistance measurements with a bright 0.3-inch red LED display featuring function and range annunciation.

Technical Specifications Display & Resolution

3-1/2 digit, 7-segment red LED display, 0.3-inch character height

Automatic polarity sensing and display

Function and range annunciation included Voltage Measurement

DC Voltage: ±200 mV to ±1200 V ranges; 100 μV sensitivity on 200 mV range; 10 MΩ ±1% input resistance; ±(0.05% of reading + 2 digits) accuracy on 200 mV range; maximum input 1200 V (DC + peak AC); 1.6 second response time

AC Voltage: 200 mV to 1200 V ranges; average-responding, RMS-calibrated converter; 100 μV sensitivity on 200 mV range; 5 MΩ resistance input impedance; ±1.5% of reading ±3 digits (30–50 Hz); ±0.3% of reading ±3 digits (50 Hz–20 kHz); maximum input 1700 V (DC + peak AC), 107 Vrms at 10 kHz Current Measurement

DC Current: 200 µA to 2000 mA ranges; ±(0.2% of reading + 2 digits) accuracy on 200 µA range; 250 V rms input protection; 120 dB common mode rejection at 50/60 Hz ±0.1% with 1 kΩ unbalance

Key Features

Autoranging and manual range selection for enhanced measurement flexibility

Fast response times: 1.6 seconds for voltage measurements, <0.7 seconds for current

High input resistance (10 MΩ DC, 5 MΩ AC) minimizes circuit loading

Dual-range AC frequency response: 30 Hz to 100 kHz

Temperature-compensated accuracy specifications

Typical Applications

General electronic circuit troubleshooting and verification

Precision voltage and current monitoring in lab and field environments

Resistance and continuity testing

Signal analysis across audio and low-frequency RF ranges

Specifications

ParameterValue
Frequency Range30 Hz to 100 kHz | Voltage / Current Range: DC Voltage: ±200 mV to ±1200 V
AC Voltage200 mV to 1200 V
DC Current200 µA to 2000 mA
AC Current200 µA to 2000 mA

HP / Agilent 3435A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3435A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 3435A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

HP / Agilent 3435A price

This HP / Agilent 3435A is listed at $91.78. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 3435A calibration cost

NIST-traceable calibration for the HP / Agilent 3435A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →