Advantest R6581T Digital multimeter

Advantest Laboratory Measurement Instruments. Voltage / Current Range: 100 mV to 1000 V, 100 nA to 1 A, Voltage: 300 V.

Model
Advantest R6581T
Calibration
Available on request
Price
$2,579
Status
In stock
RFQ ref
R6581T
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R6581T is an 8.5-digit digital multimeter engineered for high-precision DC measurements in laboratory, development, and quality control environments. This DC-only instrument delivers exceptional accuracy across DC voltage, DC current, and resistance measurements - both 2-wire and 4-wire configurations. The R6581T combines stability with resolution to support demanding metrology and component characterization workflows where measurement uncertainty must be tightly controlled.


Technical Specifications

Display & Resolution

  • 8.5-digit display

  • Auto-ranging capability Measurement Functions

  • DC Voltage (DCV): 100 mV to 1000 V ranges

  • DC Current (DCI): 100 nA to 1 A ranges

  • 2-wire Resistance

  • 4-wire Resistance: 10 Ω to 100 MΩ ranges DC Voltage Accuracy (1 Year)

  • 100 mV: 7 ppm (reading) + 10 ppm (range)

  • 1 V: 6 ppm (reading) + 1 ppm (range)

  • 10 V: 5 ppm (reading) + 0.2 ppm (range)

  • 100 V: 7 ppm (reading) + 1 ppm (range)

  • 1000 V: 7 ppm (reading) + 0.2 ppm (range) 4-Wire Resistance Accuracy (1 Year)

  • 10 Ω to 100 kΩ: 8–14 ppm (reading) + 0.5–20 ppm (range)

  • 1 MΩ: 50 ppm (reading) + 5 ppm (range)

  • 10 MΩ: 500 ppm (reading) + 50 ppm (range)

  • 100 MΩ: 5000 ppm (reading) + 50 ppm (range) DC Current Accuracy (1 Year)

  • 100 nA to 10 mA: 20–25 ppm (reading) + 20–400 ppm (range)

  • 100 mA: 30 ppm (reading) + 20 ppm (range)

  • 1 A: 110 ppm (reading) + 20 ppm (range) Environmental Stability

  • Temperature coefficient: 1.2 ppm/°C (DC Voltage), 3 ppm/°C (DC Current)

  • Input resistance: >10 GΩ (DC Voltage)

  • Maximum input voltage: 300 V


Key Features



  • Internal 2-source calibration

  • Data memory: up to 10,000 points

  • Input protection via clipping diodes and resistors


Typical Applications Component verification, standards calibration, precision current measurement, high-impedance resistance testing, and long-term stability monitoring in research and production environments.


Compatibility & Integration The R6581T operates as a standalone DC measurement instrument. Its data logging capability supports external integration for automated test systems requiring measurement archival.

Specifications

ParameterValue
Voltage / Current Range100 mV to 1000 V, 100 nA to 1 A

Advantest R6581T — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R6581T. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest R6581T faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Advantest R6581T price

This Advantest R6581T is listed at $2,579. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R6581T calibration cost

NIST-traceable calibration for the Advantest R6581T is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →