Agilent/Keysight 4062
The Agilent/Keysight 4062 is a specialized electronic component or module. Details on its specific function, specifications, and applications can be found in associated Agilent/Keysight documentation.
- Model
- Agilent / Keysight 4062
- Calibration
- Available on request
- Price
- $3,250
- Status
- In stock
- RFQ ref
- 4062
This unit
The Agilent/Keysight 4062 is a semiconductor parametric test system engineered for process monitoring and device characterization in integrated circuit manufacturing. This platform delivers high-precision DC measurements across current, voltage, capacitance, conductance, and pulse force parameters, supported by an intelligent switching matrix capable of accessing up to 96 measurement pins. The system executes spot, sweep, pulse, pulse sweep, and analog search measurement modes with frequency capability to 500 kHz and precision to 0.05%.
Technical Specifications
- Measurement Parameters: DC current, DC voltage, capacitance, conductance, pulse force
- DC Measurement Modes: Spot, sweep, pulse, pulse sweep, analog search
- Frequency Range: Up to 500 kHz
- Measurement Precision: Up to 0.05%
- Source/Monitor Unit (SMU) Current Range: ±20 fA to ±1 A (standard); 2 pA to ±1 A (Kelvin configuration)
- Source/Monitor Unit (SMU) Voltage Range: ±40 µV to ±200 V (standard); ±40 µV to ±200 V (Kelvin configuration)
- Voltage/Voltage-Measurement Unit (VS/VMU) Output Range: ±1 mV to ±40 V
- VS/VMU Measurement Range: ±40 µV to ±40 V; ±4 µV to ±2 V (differential mode)
- Switching Matrix: Up to 96 measurement pins with 17 instrument ports (all ports access all pins)
- Source/Monitor Units: 1 high-resolution SMU, 1 high-current SMU (Kelvin), 2 Kelvin SMUs, 1 ground unit (Kelvin)
- Auxiliary Voltage Ports: 4 ports
- Connect-Force-Measure Sequence: Typical resistance measurement completes in less than 17 ms
Key Features
- HP BASIC/UX operating environment with HP-UX (System V UNIX) platform
- Interactive Measurement and Analysis (IMA) Software with softpanel interface for interactive parametric testing
- SPECS and SPECS-FA software compatibility
- Configurable pin card options (48 or 96 pins via HP 4085A/B or HP 4089A switching matrices)
- Data acquisition across multiple test points with flexible instrument port allocation
Typical Applications
- Process monitoring in semiconductor manufacturing
- Device characterization and parametric testing
- Integrated circuit development and yield optimization
Compatibility & Integration Available in HP 4062C, HP 4062UX, and HP 4062F configurations. Supports standard networking for remote operation. Compatible with auxiliary instrumentation such as LCR meters (e.g., HP 4284A, 20 Hz–1 MHz).
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | Up to 500 kHz | Voltage / Current Range: 2 pA to ±1 A (SMU Kelvin) |
| Voltage | ±40 µV to ±200 V (SMU) |
| VS/VMU output ±1 mV to ±40 V, Current | ±20 fA to ±1 A (SMU standard), measurement ±40 µV to ±40 V (±4 µV to ±2 V differential) |
Agilent / Keysight 4062 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 4062. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 4062 faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.
Agilent / Keysight 4062 price
This Agilent / Keysight 4062 is listed at $3,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 4062 calibration cost
NIST-traceable calibration for the Agilent / Keysight 4062 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →