HP / Agilent 4352B 3 Ghz Signal Analyzer

HP / Agilent Microwave Analyzers. Resolution: Measurement range ÷ 40, Accuracy: ±(Measurement range × 0.1% + external timebase a, Resolution: 50 Hz.

Model
HP / Agilent 4352B
Calibration
Available on request
Price
$2,070
Status
In stock
RFQ ref
4352B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 4352B is a dual-mode signal analyzer for characterizing Voltage Controlled Oscillators (VCOs) and Phase-Locked Loops (PLLs) in RF wireless applications. Operating as both a signal analyzer and VCO tester, it covers 100 MHz to 3 GHz natively, with extension to 12.6 GHz via the optional HP 43521A downconverter. The instrument delivers laboratory-grade analysis for design validation alongside production-line measurement speed.

Technical Specifications Frequency Measurement

Measurement range: 100 MHz to 3 GHz

Frequency span: 2 MHz, 20 MHz, MAX

Resolution: Measurement range ÷ 40,000 Hz

Accuracy: ±(Measurement range × 0.1% + external timebase accuracy)

Transient resolution: 50 Hz; time resolution: 12.5 µs RF Power Measurement

Input range: −10 to +20 dBm

Absolute accuracy: ±3 dBm @ −10 dBm, RF ATT = 10 dB (typical)

Relative accuracy: 0.5 dB (typical)

Input impedance: 50 Ω; VSWR <1.5 (@ <2 GHz), <1.3 (typical) Phase Noise Measurement

Performance: −157 dBc/Hz @ 1 MHz offset (typical)

Measurement points: Up to 801 from 100 Hz to 10 MHz offset

Sweep time: 7.4 seconds

Carrier lock: Automatic via carrier lock multi-mode PLL technology Spectrum Analysis

FFT spectrum analyzer capability included FM Deviation

Range: 0 to 200 kHz peak

Accuracy: ±(2% + 0.1% of measurement) @ 1 kHz FM rate DC Control & Power Supply

VCO tuning supply: 0 to +15.5 V, 50 mA max.; 1 mV resolution; ±(0.2% + 2 mV) accuracy

Control voltage source: 0 to +20 V, 100 µV steps, 20 mA max.; ±(0.1% + 20 mV) accuracy (Option 001: −15 to +35 V)

Control voltage noise: <1 nV/√Hz @ 10 kHz offset Filtering & Signal Generation

HP filters: 50 Hz, 300 Hz

LP filters: 3 kHz, 15 kHz, 20 kHz

1 kHz signal source for VCO characterization

Residual FM: <3 Hz rms (300 Hz – 3 kHz bandwidth)

Key Features

Dual measurement modes: signal analyzer and VCO tester

Excellent phase noise characterization with automatic carrier tracking

Integrated DC supply and ultra-low-noise control voltage source for complete VCO tuning evaluation

High frequency resolution and transient measurement capability

GPIB interface for automated test sequences

Typical Applications

VCO characterization and tuning curve generation

PLL phase noise and transient response evaluation

RF component validation in wireless transceiver design

Production-line acceptance testing of oscillators

Compatibility & Integration

Extends to 12.6 GHz with HP 43521A downconverter option

DC control voltage source supports Option 001 extended polarity range (−15 to +35 V)

GPIB control for integration into automated measurement systems

Specifications

ParameterValue
Frequency Range100 MHz to 3 GHz (extends to 12.6 GHz with HP 43521A downconverter) | Power Range (dBm): −10 to +20 dBm | Voltage / Current Range: VCO supply: 0 to +15.5 V @ 50 mA max.
Control voltage0 to +20 V @ 20 mA max. (Option 001: −15 to +35 V)

HP / Agilent 4352B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 4352B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

HP / Agilent 4352B price

This HP / Agilent 4352B is listed at $2,069.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 4352B calibration cost

NIST-traceable calibration for the HP / Agilent 4352B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →