ABB / Kent-Taylor 442R Pneumatic Indicating Controller

The ABB Kent-Taylor 442R is a pneumatic indicating controller designed for precise process control in industrial applications. It offers reliable monitoring and adjustment of pressure, temperature, flow, and level, featuring a clear indication display and solid pneumatic control mechanism for accurate and dependable operation.

Model
ABB / Kent-Taylor 442R
Calibration
Available on request
Price
$1,599
Status
In stock
RFQ ref
442R
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The ABB Kent-Taylor 442R is a pneumatic indicating controller that delivers proportional plus integral control for precise process regulation. It accepts a 3 to 15 psi pneumatic input signal and outputs a proportional pneumatic control signal, making it suitable for monitoring and adjusting pressure, temperature, flow, and level across industrial processes. The unit features dual digital displays for programming and indication, LED alarm status indicators, and intuitive membrane-switch controls for real-time parameter adjustment.


Technical Specifications

Control Authority

  • Proportional plus Automatic Reset (Integral) control modes

  • Direct or reverse action operation

  • Proportional response (gain): 0.2 to 35% output per % input

  • Reset rate (integral): 0.05 to 200 repeats per minute

  • Accuracy: ±0.55% of span

  • Repeatability: 0.2%

  • Dead band: 0.2%

  • Speed of response: 6.1 ±0.5 seconds (60 Hz); 7.3 ±0.5 seconds (50 Hz) Signal Interface

  • Input: 3 to 15 psi pneumatic signal

  • Output: pneumatic control signal User Interface

  • Dual digital displays (upper and lower)

  • Three tactile membrane switches (Page Advance, Parameter Advance, Enter)

  • Rotary bit-generator for parameter value adjustment

  • Auto/Manual selector switch

  • LED indicators for alarm status (A1, A2)


Key Features



  • Adjustable proportional gain eliminates the need for external amplification or custom configurations

  • Integral reset function removes steady-state offset between setpoint and process measurement

  • Metal case construction with wall/panel mounting lugs

  • Weight: 1.6 lb (0.7 kg)

  • Setpoint, zero, proportional gain, and reset rate adjustment controls


Typical Applications Process control loops requiring setpoint regulation with offset elimination. Suitable for cascade control configurations and multi-parameter industrial monitoring.


Compatibility & Integration The optional Model 4234 power supply provides stabilized 350 mA direct current output, available in 110–120 V a.c. or 200–220/240 V a.c. versions, with cable gland entries for supply and output connections.

Specifications

ParameterValue
Voltage / Current Range110-120 VAC or 200-220/240 VAC (power supply)

ABB / Kent-Taylor 442R — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the ABB / Kent-Taylor 442R. Calibration covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common ABB / Kent-Taylor 442R faults: blown I/O fuses, failed analog modules, power supply capacitor failure. Common faults include blown I/O protection fuses, failed analog I/O modules, power supply capacitor failure, and serial or Ethernet communication port damage.

ABB / Kent-Taylor 442R price

This ABB / Kent-Taylor 442R is listed at $1,599. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

ABB / Kent-Taylor 442R calibration cost

NIST-traceable calibration for the ABB / Kent-Taylor 442R is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents