Endevco 4430A Bridge Transducer Signal Condition

The Endevco 4430A is a bridge transducer signal conditioner designed for amplifying and conditioning signals from bridge-type transducers. It provides excitation voltage, bridge completion, and signal amplification for accurate measurement in various applications.

Model
Endevco 4430A
Calibration
Available on request
Price
$1,100
RFQ ref
4430A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Endevco 4430A is a programmable bridge transducer signal conditioner designed to amplify and condition signals from full, half, or quarter bridge transducers including pressure gages, strain gage potentiometers, and ISOTRON® type accelerometers. The unit delivers isolated, true differential signal processing with extensive front-panel programmability, making it suitable for demanding industrial and laboratory measurement applications.

Technical Specifications Signal Path

True differential input with programmable AC or DC coupling

Maximum input voltage: ±50 V differential, ±300 V common mode (DC or AC peak)

Input impedance: 50 MΩ minimum (DC coupled); 1 MΩ typical (AC coupled)

Common mode rejection ratio: 120 dB minimum (DC to 60 Hz at Gain ≥100)

Isolated output; differential sensor inputs to output isolation 1000 MΩ Excitation

Isolated, programmable voltage excitation: 0.100 Vdc to 15.000 Vdc (5 mV steps)

Programmable current: 0.5 mA to 100 mA (0.1 mA steps)

Supports full, half, or quarter bridge completion Amplification

Gain range: 1 to 1000 (optional 4430A-1 extends to 10,000)

Gain accuracy: ±0.1% of setting maximum

Linearity: ±0.005% of full scale (best fit straight line, DC)

Gain sensitivity to line voltage: ±0.01% of full scale

Automatic and manual zeroing to <1 mV RTO Filtering

4-pole Butterworth low pass filter: 10 Hz to 10 kHz (5 Hz steps)

Fixed corner frequency options: 20 kHz, 30 kHz

Wideband (filters bypassed): DC to 100 kHz (-3 dB minimum)

AC coupled wideband: 2 Hz to 100 kHz (-3 dB minimum) Phase Response

Non-inverting: <2° (DC to 1 kHz); <5° (1 kHz to 10 kHz) Physical

Weight: 3.95 lbs

Front-panel programming via EDIT, MENU SELECT, LED bar graph, and ENTER keys

Five-character alphanumeric LCD display

Key Features

External calibration input (differential input switchable to calibration voltage)

High common mode voltage operation: 300 Vdc or AC peak maximum

±300 V common mode rejection enables low-noise bridge measurements in high-noise environments

Maximum 9 conductors supported for flexible transducer configurations

Typical Applications

Pressure measurement systems

Strain gage signal conditioning

ISOTRON® accelerometer signal processing

Industrial and laboratory bridge transducer data acquisition

Specifications

ParameterValue
Frequency RangeDC to 100 kHz | Voltage / Current Range: ±300 V common mode, 0.100 Vdc to 15.000 Vdc excitation

Endevco 4430A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Endevco 4430A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Endevco 4430A price

This Endevco 4430A is listed at $1,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Endevco 4430A calibration cost

NIST-traceable calibration for the Endevco 4430A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →