Keysight / Agilent / HP 44706A 60-Channel Single-Ended Relay Multiplexer
Keysight / Agilent / HP Signal Conditioning Modules. Channels: ** 60 single-ended, Voltage: ** 30 V dc or 30 V ac rms (42 V peak), Current: ** 50 mA.
- Model
- HP 44706A
- Calibration
- Available on request
- Price
- $850
- RFQ ref
- 44706A
This unit
The Keysight/Agilent/HP 44706A is a 60-channel single-ended relay multiplexer for high-density signal switching in automated test systems. It routes voltage, resistance, thermocouple, and strain gauge signals with low crosstalk and minimal offset error, integrating directly with HP 3852A data acquisition platforms. Each channel operates independently, accommodating field wiring up to 16 AWG and supporting switching rates up to 450 channels/second.
Technical Specifications
Channels: 60 single-ended
Maximum Switch Rate: 450 channels/second (with HP 3852A voltmeter)
Maximum Input Voltage: 30 V dc or 30 V ac rms (42 V peak)
Maximum Input Current: 50 mA
Maximum Input Power: 1 VArms/channel
Input Impedance: >10⁹ Ω
Bandwidth: 1.0% flatness at 1 MHz; -3 dB at 10 MHz
Crosstalk: -70 dB at 100 kHz
Maximum Offset Voltage: 200 µV
Maximum Bias Current: ±1 nAdc
Maximum Wire Size: 16 AWG
Key Features
Independent per-channel configuration
Low input impedance drift for precision measurement
Dual-module architecture: component module housing switching elements and 60-channel terminal module for field connections
Supports multiple signal types in single instrument
Typical Applications
Multi-channel voltage and resistance measurement
Thermocouple and strain gauge data acquisition
High-speed automated test environments requiring dense signal routing
Compatibility & Integration Designed for operation with the HP 3852A Data Acquisition system and compatible external voltmeters. Signals connect at the terminal module and route internally to the component module's switching matrix.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 10 MHz | Voltage / Current Range: 30 V dc or 30 V ac rms (42 V peak) |
HP 44706A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP 44706A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP 44706A price
This HP 44706A is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP 44706A calibration cost
NIST-traceable calibration for the HP 44706A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →