Datron 4600
Datron Calibration Equipment. Current: 11A, Voltage: >, Frequency range: 10 Hz to 5 kHz (standard).
- Model
- Datron 4600
- Calibration
- Available on request
- Price
- $4,500
- Status
- In stock
- RFQ ref
- 4600
This unit
The Datron 4600 Transconductance Amplifier extends the current sourcing capabilities of Datron calibrators and standards, delivering precision current generation up to 11A DC or RMS AC. It operates in two modes: Slave Mode integrates with Datron 4700 series calibrators for automated control via the Autocal technique, while Solo Mode functions as a standalone amplifier driven by external voltage sources. The unit converts voltage input to current output at a 1:1 transfer characteristic (1A output per 1V input). This dual-mode architecture suits calibration laboratories and metrology applications requiring high-current generation with verifiable accuracy across frequency ranges from 10 Hz to 20 kHz.
Technical Specifications Current Output
Maximum DC current: 11A
Maximum AC RMS current: 11A
Compliance voltage: >2V
Input impedance: 300 kΩ in parallel with 100 pF
Input isolation: 100V pk (input to chassis) DC Current Accuracy
Slave Mode: ±80 ppm output ±500 µA (90-day, 23°C ±1°C)
Solo Mode: ±125 ppm (0 to 11A, 90-day ±1°C); Temperature coefficient 7 ppm/°C (23°C ±10°C) AC Current Accuracy
Slave Mode: ±(330 ppm output + 1.1 mA) at 10 Hz–1 kHz; ±(0.1% output + 1.4 mA) at 1–5 kHz
Solo Mode: ±430 ppm (0.9–11A, 10 Hz–5 kHz). Frequency-dependent: +(200 ppm output + 1.1 mA) 10 Hz–1 kHz; ±(700 ppm output + 1.4 mA) 1–5 kHz; ±(1400 ppm output + 6 mA) 5–10 kHz; +(0.54% output + 33 mA) 10–20 kHz. Temperature coefficients: 10 ppm/°C (5 kHz) AC Performance
Total harmonic distortion: 0.1% (10 Hz–1 kHz), 0.5% (1–5 kHz), 1.0% (5–10 kHz), 1.5% (10–20 kHz)
Frequency range: 10 Hz to 5 kHz (standard); 10 Hz to 20 kHz (extended)
Key Features
Transfer characteristic of 1A output per 1V input in Solo Mode
Programmable output via calibrator front panel or IEEE-488 interface (Slave Mode)
Autocal-based automated recalibration capability
Requires specific lead kit (Datron Part Number 440151) for Slave Mode operation
Compatibility & Integration Slave Mode supports Datron 4700 series calibrators (firmware 5.0 and above), including models 4707, 4705, and 4708. Solo Mode operates with any suitable external voltage source.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 20 kHz | Voltage / Current Range: 200 mV to 20 kV DC |
Datron 4600 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Datron 4600. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Datron 4600 price
This Datron 4600 is listed at $4,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Datron 4600 calibration cost
NIST-traceable calibration for the Datron 4600 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →