Agilent/Keysight 5347A

Agilent / Keysight Frequency Counters. Frequency Range: Input 1: 500 MHz to 20.0 GHz; Input 2: 10 Hz to 525 MHz, Power Range (dBm): −70 dBm to +20 dBm (power meter, sensor-dependent), Voltage / Current Range: Input 1: +7 dBm maximum; Input 2: +10 dBm (50 Ω) or 1 V rms (1 MΩ) maximum.

Model
Agilent / Keysight 5347A
Calibration
Available on request
Price
$2,500
Status
In stock
RFQ ref
5347A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 5347A is a dual-channel frequency counter and power meter combining microwave measurement capability in a portable instrument. Input 1 covers 500 MHz to 20.0 GHz with sensitivity down to −32 dBm (500 MHz to 12.4 GHz) and −27 dBm (12.4 GHz to 20.0 GHz). Input 2 extends low-frequency coverage from 10 Hz to 525 MHz at 25 mV rms sensitivity.


The power meter operates across 0 MHz to 20 GHz with −70 dBm to +20 dBm range, sensor-dependent, delivering 50 dB dynamic range in 10 dB steps.


Technical Specifications

Frequency Counter

Input 1 (Type N, female)



  • Frequency range: 500 MHz to 20.0 GHz

  • Sensitivity: −32 dBm to −35 dBm (500 MHz–12.4 GHz); −27 dBm to −32 dBm (12.4 GHz–20.0 GHz)

  • Maximum input: +7 dBm; damage level +25 dBm peak

  • Resolution: 1 Hz or 10 kHz, selectable

  • Tracking speed: 1 MHz/sec (1 Hz) or 1 GHz/sec (10 kHz)

  • Acquisition time: <125 ms (1 Hz) or 6 dB above signals within 500 MHz; >20 dB above signals within 500 MHz to 20 GHz Frequency Counter


Input 2 (BNC, female)



  • Frequency range: 10 Hz to 525 MHz

  • Sensitivity: 25 mV rms (15 mV rms typical)

  • Impedance: 1 MΩ nominal shunted 5 kHz, 50 Ω)

  • Resolution: 1 Hz or 10 kHz, selectable Power Meter

  • Frequency range: 0 MHz to 20 GHz (sensor-dependent)

  • Power range: −70 dBm to +20 dBm (sensor-dependent)

  • Supported sensors: HP 8481A, HP 8481D, HP 8484A, HP 8485A

  • Dynamic range: 50 dB in 10 dB steps

  • Display units: Watts, dBm

  • Resolution: 0.01 dB logarithmic


Key Features



  • Five-key user interface simplifies operation

  • Optional internal battery: up to 2 hours cordless operation

  • Dual-input architecture: microwave (N-type) and low-frequency (BNC) channels

  • AC-coupled inputs on both channels

  • Modulation tolerance: any AM index; FM up to 10 MHz


Compatibility & Integration



  • Compatible with HP power sensors (8481A, 8481D, 8484A, 8485A)

  • Optional HP-IB interface for ATE system integration and manual mode control (±60 MHz deviation)

Specifications

ParameterValue
Frequency Range10 Hz to 20 GHz (Input 1)
10 MHz to 20 GHz (Power Meter) | Power Range (dBm)'-70 dBm to +20 dBm | Voltage / Current Range: dc–5 kHz), Input 2: 25 mV rms (15 mV typical)
Damage250 V dc + ac peak (50 Ω or 1 MΩ

Agilent / Keysight 5347A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 5347A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 5347A price

This Agilent / Keysight 5347A is listed at $2,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 5347A calibration cost

NIST-traceable calibration for the Agilent / Keysight 5347A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents