This unit

The Agilent/Keysight 54100A is a digitizing oscilloscope engineered for acquisition and analysis of complex analog and digital signals. It delivers 1 GHz bandwidth with a 40 MSa/s sampling rate and 10-bit vertical resolution, supporting averaging for enhanced measurement fidelity. Deep memory architecture enables effective capture depths of millions of bytes through random repetitive sampling, allowing investigation of infrequent transient events occurring well before the trigger point.


Technical Specifications



  • Bandwidth: 1 GHz (-3 dB)

  • Sampling Rate: 40 MSa/s

  • Vertical Resolution: 10 bits (with averaging)

  • Memory Depth: 1 kbyte per channel; effective depth of millions of bytes via random repetitive sampling

  • Time Base Accuracy: 0.002%

  • Time Resolution: 10 ps

  • Transition Time (10%–90%): ≤350 ps

  • Deflection Factor: 10 mV/div to 1 V/div in 1-2-5 steps

  • DC Accuracy (Single Voltage Marker): ±3% of full-scale + 2% of offset (50 Ω source)

  • DC Delta Voltage Accuracy: +1% of full-scale −3% of reading (50 Ω source)

  • DC Offset Range: ±1.5× full-scale (center-screen referenced)

  • Maximum Input Voltage: 40 V DC + peak AC

  • Vertical Magnifier: 1× to 16× expansion in 0.5% steps


Key Features



  • Dual analog input channels

  • Single external trigger input

  • Trigger source selection: Channel 1, Channel 2, or Trigger 3 input

  • 7-inch rack height form factor


Typical Applications High-speed circuit design, transient waveform capture, signal integrity analysis, and time-domain measurements requiring sub-nanosecond timing resolution.


Compatibility & Integration Accepts HP 54000-series input pods (sold separately). Compatible with HP 54002A 50 Ω input pod and active oscilloscope probes requiring 50 Ω inputs. Supports active probes such as the HP 54001A (1 GHz bandwidth, 1 V/div gain, 10 kΩ input impedance). Legacy Status: No longer manufactured. Service documentation available for reference.

Specifications

ParameterValue
Frequency Range1 GHz | Voltage / Current Range: ±1.5 × full-scale DC offset

Agilent / Keysight 54100A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 54100A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 54100A price

This Agilent / Keysight 54100A is listed at $4,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 54100A calibration cost

NIST-traceable calibration for the Agilent / Keysight 54100A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →