HP / Agilent 54751A 20 GHz dual channel electrical module

HP / Agilent Modular Instrument Chassis. Channels: ** 2, Bandwidth: ** 12.4 GHz (low) or 20 GHz (high) per channel, Resolution: ** 12 bits standard.

Model
HP / Agilent 54751A
Calibration
Available on request
Price
$1,065
Status
In stock
RFQ ref
54751A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 54751A is a dual-channel electrical module for high-frequency signal acquisition up to 20 GHz. This plug-in module installs into compatible Agilent/Keysight mainframe oscilloscopes to enable precise measurement of fast transient and periodic signals across communications, semiconductor, and signal-integrity applications. User-selectable bandwidth (12.4 GHz or 20 GHz per channel) balances measurement speed against noise performance, with rise times as low as 17.5 ps in high-bandwidth mode.

Technical Specifications

Channels: 2

Bandwidth: 12.4 GHz (low) or 20 GHz (high) per channel, DC-coupled

Rise Time: ≤17.5 ps (high BW) / ≤28.2 ps (low BW)

Vertical Resolution: 12 bits standard; 15 bits with averaging

Vertical Accuracy: 0.4% of full-scale or marker reading (greater of the two) ± 2 mV ± 1.2% of (reading – channel offset)

Noise (RMS): ≤1 mV (high BW) / ≤0.5 mV (low BW); reduces to ~50 µV or ~25 µV with averaging

Sensitivity Range: 1 mV/div to 100 mV/div

Dynamic Range: ±400 mV relative to channel offset

Trigger Channel Bandwidth: 2.5 GHz internal; up to 18 GHz with HP 54118A

External Trigger Bandwidth: 2.5 GHz or 12 GHz selectable

Trigger Modes: Normal and High Sensitivity (hysteresis off)

Trigger BW Limit: ~100 MHz low-pass filter

Attenuation Scaling: 0.0001:1 to 1,000,000:1 configurable

Connectors: 3.5 mm and SMA (male)

Key Features

Independent bandwidth selection per channel optimizes noise vs. fidelity tradeoff

12-bit ADC expandable to 15-bit via averaging reduces measurement uncertainty

Configurable scale factors from 1 mV/div in fine 0.1 mV increments or standard 1-2-5-10 sequence

Two-wide module configuration supports up to four total channels in HP 54750A

Compatibility & Integration The 54751A installs into:

HP/Agilent 54750A High-Bandwidth Digitizing Oscilloscope Mainframe

Agilent 83480A Digital Communications Analyzer Mainframe

Agilent/Keysight 86100A/B/C Infiniium DCA/DCA-J Mainframes

Specifications

ParameterValue
Frequency RangeDC to 20 GHz | Voltage / Current Range: ±400 mV dynamic range

HP / Agilent 54751A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 54751A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

HP / Agilent 54751A price

This HP / Agilent 54751A is listed at $1,065.4. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 54751A calibration cost

NIST-traceable calibration for the HP / Agilent 54751A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →