Agilent/Keysight 54854A

Agilent / Keysight Digital Oscilloscopes. Accuracy: ±(2% of channel offset + 1% of full scale), Dynamic range: ±4 div from center screen, Resolution: sample rate/memory depth.

Model
Agilent / Keysight 54854A
Calibration
Available on request
Price
$2,500
Status
In stock
RFQ ref
54854A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 54854A is a 4 GHz digital oscilloscope engineered for signal integrity validation in telecommunications, semiconductor design, and digital systems development. This Infiniium 54800 series instrument captures and analyzes complex waveforms with 4 analog input channels, 20 GSa/s simultaneous sampling across all channels, and up to 32 Mpts acquisition memory at reduced sample rates. The Windows-based interface streamlines both real-time troubleshooting and detailed design verification workflows.


Technical Specifications

Analog Channels & Bandwidth

  • 4 analog input channels

  • 4 GHz analog bandwidth

  • 20 GSa/s sample rate on all four channels simultaneously Acquisition Memory

  • Up to 1 Mpts MegaZoom deep memory at all sample rates

  • Up to 32 Mpts MegaZoom deep memory at 2 GSa/s and slower

  • 262 kpts/ch acquisition memory Vertical System

  • Sensitivity range: 1 mV/div to 1 V/div

  • Offset range: > ±12 div or ±4 V (whichever is smaller)

  • Offset accuracy: ±(2% of channel offset + 1% of full scale)

  • Dynamic range: ±4 div from center screen

  • Electronic attenuators eliminate mechanical relay concerns Horizontal System

  • Main sweep: 5 ps/div to 20 s/div

  • Delayed sweep: 1 ps/div to main time base setting Triggering

  • Trigger jitter: 1.0 ps rms

  • Advanced modes: violation, setup/hold, pulse width, transition triggers

  • Trigger coupling: DC, AC (7 Hz), low-frequency reject (50 kHz), high-frequency reject (50 kHz) Waveform Analysis

  • 4 simultaneous math functions: add, subtract, multiply, divide, average, differentiate, integrate, invert, magnify, min, max, FFT magnitude, FFT phase, common mode, smoothing

  • FFT range: DC to 10 GHz

  • FFT resolution: sample rate/memory depth

  • Signal-to-noise ratio: 60 dB at 32k memory depth

  • Window modes: Hanning, flattop, rectangular

  • Mask testing with AutoMask and user-defined templates

  • Jitter analysis for cycle-cycle, N-cycle, and time/rate measurements


Key Features



  • Deep acquisition memory for extended signal capture across all channels

  • Picosecond-level trigger timing precision

  • Flexible FFT analysis from DC to 10 GHz

  • Pass/fail mask testing against predefined or custom templates

  • Electronic vertical attenuators for improved reliability


Typical Applications



  • High-speed digital signal validation

  • Telecommunications protocol analysis

  • Semiconductor characterization and design debug

  • Jitter and timing analysis in clock and data signals

  • Multi-channel signal correlation and integrity assessment


Compatibility & Integration Jitter analysis capabilities expand with E2681A EZJIT or N5400A EZJIT Plus software options. Communications mask test kits available for industry-specific compliance validation.

Agilent / Keysight 54854A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 54854A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 54854A price

This Agilent / Keysight 54854A is listed at $2,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 54854A calibration cost

NIST-traceable calibration for the Agilent / Keysight 54854A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →