Emerson / Rosemount Analytical 54EC-01-09 Conductivity / Resistivity Analyzer / Controller

The Emerson Rosemount Analytical 54EC-01-09 is a conductivity/resistivity analyzer and controller designed for industrial applications. It accurately measures and controls conductivity or resistivity in liquids, ensuring process efficiency and product quality. It features a user-friendly interface, solid construction, and versatile output options for seamless integration with control systems.

Model
Emerson / Rosemount Analytical 54EC-01-09
Calibration
Available on request
Price
$1,250
Status
In stock
RFQ ref
54EC-01-09
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Emerson Rosemount Analytical 54EC-01-09 is a conductivity/resistivity analyzer and controller for inline process monitoring and control of liquid solutions. It measures conductivity, resistivity, and percent concentration using contacting or inductive sensors, delivering ±0.5% accuracy with contacting probes across a 0–20,000 µS/cm range. The unit accommodates toroidal inductive sensors to 2 S/cm with ±1% accuracy and supports temperature measurement from −15 to 200°C. Temperature compensation operates automatically or manually, with selectable correction algorithms for high-purity water, cation conductivity, or linear temperature coefficients (0.0 to 5.00%/°C).

Technical Specifications Measurement Ranges

Contacting sensors: 0–20,000 µS/cm

Inductive (toroidal) sensors: 0–2 S/cm

Temperature: −15 to 200°C (5 to 392°F) Accuracy & Stability

Contacting sensors: ±0.5% of reading

Inductive sensors (200 µS/cm to 2 S/cm): ±1% of reading

Repeatability: ±0.25% of reading

Stability: ±0.25% of output range per month (non-cumulative)

Ambient temperature coefficient: ±0.01% of reading/°C Electrical

Power supply: 115–230 VAC, 50/60 Hz, ±10% or 28 VDC @ 6 A

Power consumption: 8 W maximum Outputs & Communication

Two isolated 4–20 mA or 0–20 mA analog outputs (500 Ω maximum load)

HART® digital signaling superimposed on Output 1

Four relays: three Form A (SPST, normally open); one Form C (SPDT) fault alarm

Configurable for process, temperature, or interval timer functions with programmable setpoints and adjustable hysteresis

Key Features

NEMA 4X (IP65) cast aluminum enclosure with weatherproof, corrosion-resistant construction

Back-lit dot-matrix LCD display and membrane keyboard interface

DIN-size package: 144 × 144 × 132 mm (5.7 × 5.7 × 5.2 inches)

Independent temperature compensation with four algorithm options

Relay-activated chemical cleaning timer at user-defined intervals

Sensor diagnostics output assignment

Typical Applications

High-purity water quality monitoring

Cation conductivity measurement in deionization systems

Industrial process water control

Harsh environment deployments requiring IP65 protection

Compatibility & Integration Works with both contacting electrode and toroidal inductive sensor technologies. HART® protocol enables digital communication over standard 4–20 mA wiring for advanced diagnostics and remote configuration.

Specifications

ParameterValue
Voltage / Current Range±10% or 28 VDC @ 6 A, 115–230 VAC, 50/60 Hz

Emerson / Rosemount Analytical 54EC-01-09 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Emerson / Rosemount Analytical 54EC-01-09. Calibration covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Emerson / Rosemount Analytical 54EC-01-09 faults: blown I/O fuses, failed analog modules, power supply capacitor failure. Common faults include blown I/O protection fuses, failed analog I/O modules, power supply capacitor failure, and serial or Ethernet communication port damage.

Emerson / Rosemount Analytical 54EC-01-09 price

This Emerson / Rosemount Analytical 54EC-01-09 is listed at $1,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Emerson / Rosemount Analytical 54EC-01-09 calibration cost

NIST-traceable calibration for the Emerson / Rosemount Analytical 54EC-01-09 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents